Effects of lower limb and pelvic pin positions on leg length and offset measurement errors in experimental total hip arthroplasty

Author:

Kawamura HaruoORCID,Watanabe Yasuhiko,Nishino Tomofumi,Mishima Hajime

Abstract

Abstract Background Leg length (LL) and offset (OS) are important factors in total hip arthroplasty (THA). Because most LL and OS callipers used in THA depend on fixed points on the pelvis and the femur, limb position could affect measurement error. This study was conducted on a THA simulator to clarify the effects of lower limb position and iliac pin position on LL and OS errors and to determine the permissible range of limb position for accurate LL and OS measurement. Methods An LL and OS measurement instrument was used. Two pin positions were tested: the iliac tubercle and the top of the iliac crest intersecting with the extension of the femoral axis. First, the limb was moved in one direction (flexion-extension, abduction-adduction, or internal-external rotation), and LL and OS were measured for each pin position. Next, the limb was moved in combinations of the three directions. Then, the permissible range of combined limb position, which resulted in LL and OS measurement error within ±2 mm, was determined for each pin position. Results Only 4° of abduction/adduction caused 5–7 mm error in LL and 2–4 mm error in OS, irrespective of pin position. The effects of flexion–extension and internal–external rotation on LL error were smaller for the top of the iliac crest than for the iliac tubercle, though OS error was similar for both pin positions. For LL, the permissible range of the combined limb position was wider for the top of the iliac crest than for the iliac tubercle. Conclusion To minimize LL and OS measurement errors in THA, adduction–abduction must be maintained. The iliac pin position in the top of the iliac crest is preferred because it provides less LL measurement error and a wider permissible range of combined limb position for accurate LL measurement.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3