Relationship of Pelvic Positional Change with Leg Length and Offset Measurement in Experimental Total Hip Arthroplasty

Author:

Kikuchi Naoya1ORCID,Kawamura Haruo2,Nishino Tomofumi1,Mishima Hajime1

Affiliation:

1. Department of Orthopaedic Surgery, Faculty of Medicine University of Tsukuba 1‐1‐1 Tennodai, Tsukuba Ibaraki 305‐8575 Japan

2. Department of Orthopaedic Surgery North Prefecture Medical Center, Takahagi Kyodo Hospital 1006‐9 Agehocho, Kamitetsuna, Takahagi Ibaraki 318‐0004 Japan

Abstract

ObjectiveDuring total hip arthroplasty (THA), both pelvic and femur positions affect leg length (LL) and offset (OS) measurements because LL and OS calipers depend on the fixed reference points on the pelvis and femur, respectively. However, LL and OS measurement errors because of pelvic positional changes have not been described. This study aimed to clarify the effects of pelvic positional changes on LL and OS measurements in relation to the pelvic reference using a THA simulator.MethodsWe developed an experimental THA simulator using Sawbones models of the hemipelvis and femur that facilitated modification of the obliquity, tilt, and rotation of the pelvis. Using an LL and OS caliper, LL and OS measurement errors due to pelvic positional changes were determined with the femoral position fixed. Measurements were performed from two pelvic reference positions: the iliac tubercle (P1) and the top of the iliac crest intersecting the line of the femoral long axis (P2).ResultsConcerning pelvic obliquity, the total error of LL was 25.0 mm in P1 and 26.5 mm in P2, while the total error of OS was 13.0 mm in P1 and 10.9 mm in P2. For pelvic tilt, the total error of LL was 9.0 mm in P1 and 3.8 mm in P2, while the total error of OS was 0.5 mm in P1 and 1.0 mm in P2. Regarding pelvic rotation, the total error of LL was 13.8 mm in P1 and 3.2 mm in P2, while the total error of OS was 3.8 mm in P1 and 4.0 mm in P2.ConclusionsPelvic positional changes alter LL and OS measurements. The acceptable range (error <2 mm) on LL and OS measurement errors of pelvic obliquity was only 2°, regardless of the pelvic reference position. The pelvic reference position should be at the top of the iliac crest intersecting the line of the long axis of the femur because of a small LL measurement error with pelvic tilt and rotation.

Publisher

Wiley

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3