Effects of pelvic obliquity and limb position on radiographic leg length discrepancy measurement: a Sawbones model

Author:

Hamad Mohammed NazmyORCID,Livshetz Isaac,Sood Anshum,Patetta Michael,Gonzalez Mark H.,Amirouche Farid A.

Abstract

Abstract Purpose Potential sources of inaccuracy in leg length discrepancy (LLD) measurements commonly arise due to postural malalignment during radiograph acquisition. Preoperative planning techniques for total hip arthroplasty (THA) are particularly susceptible to this inaccuracy, as they often rely solely on radiographic assessments. Owing to the extensive variety of pathologies that are associated with LLD, an understanding of the influence of malpositioning on LLD measurement is crucial. In the present study, we sought to characterize the effects of varying degrees of lateral pelvic obliquity (PO) and mediolateral limb movement in the coronal plane on LLD measurement error (ME). Methods A 3-D sawbones model of the pelvis with bilateral femurs of equal-length was assembled. Anteroposterior pelvic radiographs were captured at various levels of PO: 0°, 5°, 10°, and 15°. At each level of PO, femurs were individually rotated medio-laterally to produce 0°, 5°, 10°, and 15° of abduction/adduction. LLD was measured radiographically at each position combination. For all cases of PO, the right-side of the pelvis was designated as the higher-side, and the left as the lower-side. Results At 0° PO, 71% of tested variations in femoral abduction/adduction resulted in LLD ME < 0.5-cm, while 29% were ≥ 0.5-cm, but < 1-cm. ME increased progressively as one limb was further abducted while the contralateral limb was simultaneously further adducted. The highest ME occurred with one femur abducted 15° and the other adducted 15°. Similar magnitudes of ME were seen in 98% of tested femoral positions at 5° of PO. The greatest ME (~ 1 cm) occurred at the extremes of right-femur abduction and left-femur adduction. At 10° of PO, a higher prevalence of cases exhibited LLD ME > 0.5-cm (39%) and ≥ 1-cm (8%). The greatest errors occurred at femoral positions similar to those seen at 5° of PO. At 15° of PO, half of tested variations in femoral position resulted in LLD ME > 1-cm, while 22% of cases produced errors > 1.5-cm. These clinically significant errors occurred at all tested variations of right-femur abduction, with the left-femur in either neutral position, abduction, or adduction. Conclusion This study aids surgeons in understanding the magnitude of radiographic LLD ME produced by varying degrees of PO and femoral abduction/adduction. At a PO of ≤5°, variations in femoral abduction/adduction of up to 15° produce errors of marginal clinical significance. At PO of 10° or 15°, even small changes in mediolateral limb position led to clinically significant ME (> 1-cm). This study also highlights the importance of proper patient positioning during radiograph acquisition, demonstrating the need for surgeons to assess the quality of their radiographs before performing preoperative templating for THA, and accounting for PO (> 5°) when considering the validity of LLD measurements.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3