Abstract
Abstract
Background
There is currently a lack of guidelines for clinicians regarding titanium hypersensitivity in implant dentistry. Diagnostic tests such as the epicutaneous test or the lymphocyte transformation test showed inconsistent results regarding reliability and validity and thus, evidence-based consensus recommendations regarding diagnostic and therapeutic options may be helpful in clinical decision-making. Therefore, the German S3 guideline on titanium hypersensitivity in implant dentistry was developed.
Findings
In the objectives, procedure, voting method and venue were defined and the consensus participants were invited. A systematic literature research was performed, and the overall quality of the evidence was rated according to the GRADE working group. Eight recommendations were formulated within the framework of a structured consensus conference under independent moderation and could be voted on with strong consensus (> 95% agreement). The formulated statements and recommendations were developed in small groups according to the guidelines of the Association of the Scientific Medical Societies in Germany (AWMF) and were discussed and agreed upon in the plenum.
Conclusions
For reasonable decision-making, a patient’s clinical symptoms should be regarded as leading parameters, which are usually expressed by a local inflammatory reaction with subsequent disturbed osseous integration. Allergy tests, such as the epicutaneous test or the lymphocyte transformation test are not helpful in titanium intolerance assessments, since these tests indicate T cell-mediated allergies, which are not observed in titanium intolerance reactions. Other metals and impurities that might be present in superstructures or alloys also need to be considered as the cause of an intolerance reaction and a trigger for contact sensitization. In the case of a suspected titanium particle-related, local immunologically induced inflammatory reaction with subsequent impaired osseous integration, dental ceramic implants can be considered as a therapeutic option.
Graphical Abstract
Publisher
Springer Science and Business Media LLC
Reference14 articles.
1. Higgins JPT, Altman DG, Gøtzsche PC, Jüni P, Moher D, Oxman AD, et al. The Cochrane Collaboration’s tool for assessing risk of bias in randomised trials. BMJ. 2011;343:d5928.
2. Wells G, Shea B, O'Connell D, Peterson J, Welch V, Losos M, et al. The Newcastle–Ottawa Scale (NOS) for assessing the quality of non-randomized studies in meta-analysis. 2000.
3. Carmen Moga BG, Schopflocher D, Harstall C. Development of a quality appraisal tool for case series studies using a modified Delphi technique. 2012.
4. Müller-Heupt LK, Schiegnitz E, Kaya S, Jacobi-Gresser E, Kämmerer PW, Al-Nawas B. Diagnostic tests for titanium hypersensitivity in implant dentistry: a systematic review of the literature. Int J Implant Dent. 2022;8(1):29.
5. Sicilia A, Cuesta S, Coma G, Arregui I, Guisasola C, Ruiz E, et al. Titanium allergy in dental implant patients: a clinical study on 1500 consecutive patients. Clin Oral Implants Res. 2008;19(8):823–35.
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献