Abstract
Abstract
Background
An accurate impression is crucial to the long-term success of dental implants. This investigation evaluated the accuracy of the open and closed implant impression techniques in partially edentulous patients who received two adjacent implants.
Material and methods
Forty patients received Osstem Implants (Osstem Implant System, Seoul, Korea). Two impressions were made for each patient, one using an open tray and a second with a closed tray technique. The horizontal distances between two impression copings were measured and compared to similar measurements on the master casts. Also, under a stereomicroscope (AmScop14370, Myford Road, #150, Irvine, CA 92606 USA) at a 50-fold magnification, the presence or absence of the marginal discrepancies was evaluated.
Results
There were no statistically significant differences regarding horizontal measurements and in the marginal relationship for the two impression techniques, except between the anterior and posterior regions, for the closed tray technique. There were also no statistically significant differences in the impression accuracy between maxillary and the mandibular arches. In addition, there were no statistically significant differences for the intraoral horizontal distances, compared to similar horizontal measurements on master casts, between the open and closed tray techniques.
Conclusions
Within the limitations of the present study, there were generally no differences in the impression accuracy between the open and closed tray techniques in partially edentulous patients with two adjacent implants.
Publisher
Springer Science and Business Media LLC
Reference29 articles.
1. Khalifa N, Allen PF, Abu-bakr NH, Abdel-Rahman ME. Factors associated with tooth loss and prosthodontic status among Sudanese adults. J Oral Sci. 2012;54:303–12.
2. Oliver RC, Brown LJ. Periodontal diseases and tooth loss. Periodontol 2000. 1993;2:117–27.
3. Hollister MC, Weintraub JA. The association of oral status with systemic health, quality of life, and economic productivity. J Dent Educ. 1993;57:901–12.
4. Ashley ET, Covington LL, Bishop BG, Breault LG. Ailing and failing endosseous dental implants: a literature review. J Contemp Dent Pract. 2003;15:35–50.
5. Sorrentino R, Gherlone EF, Calesini G, Zarone F. Effect of implant angulation, connection length, and impression material on the dimensional accuracy of implant impressions: an in vitro comparative study. Clin Implant Dent Relat Res. 2010;12(Suppl 1):e63–76.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献