Could various angulated implant depths affect the positional accuracy of digital impressions? An in vitro study

Author:

Taghva Masumeh1ORCID,Mosaddad Seyed Ali2ORCID,Ansarifard Elham13,Sadeghi Mohsen4

Affiliation:

1. Department of Prosthodontics School of Dentistry Shiraz University of Medical Sciences Shiraz Iran

2. Student Research Committee School of Dentistry Shiraz University of Medical Sciences Shiraz Iran

3. Nanomedicine and Nanobiology Research Center Department of Prosthodontics, School of Dentistry Shiraz University of Medical Sciences Shiraz Iran

4. School of Dentistry Shiraz University of Medical Sciences Shiraz Iran

Abstract

AbstractPurposeThe purpose of this in vitro investigation was to assess how implant depth could affect the three‐dimensional positional accuracy of digital impressions made from angulated implants.Materials and MethodsFour modified maxillary models were printed and divided into four study groups. In each model, two angulated implant analogs were placed at the sites of the first premolar and first molar at four different depths of 1 (G1), 2 (G2), 3 (G3), and 4 (G4) mm from the models' edentate area. Scan bodies were connected to the analogs, and one operator made 10 full‐arch scans for each master model using an intraoral scanner. Afterward, the marginal gingival part of all models was removed, and digital scans were performed for each model using a laboratory scanner to achieve a reference STL file as the control group. One‐way ANOVA and Leven's tests were used to measure and compare the 3D distance deviations across research groups after the superimposing test and control scans.ResultsA significant difference between research groups was revealed by trueness and precision analysis (p < 0.001). The trueness and precision results obtained for G1 and G4 were significantly better than those for G2 and G3 (p < 0.05).ConclusionThis study demonstrated that implant depth could affect the digital implant impressions' 3D positional accuracy.

Publisher

Wiley

Subject

General Dentistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370