Abstract
Abstract
Background
Sedation during elective fiberoptic intubation for difficult airway can cause respiratory depression, apnea and periods of desaturation. During apneic episodes, hypoxemia can be prevented by insufflation of oxygen in the deep laryngeal space. The aim of this study was to evaluate an oropharyngeal oxygenation device (OOD) designed for deep laryngeal insufflation during fiberoptic intubation.
Methods
The OOD is split in the front to form a path for the bronchoscope. An external lumen delivers oxygen in the deep laryngeal space. In this experimental study, air application (as control group), oxygen application via nasal prongs, oxygen application via the OOD, and oxygen application via the working channel of a bronchoscope were compared in a technical simulation. In a preoxygenated test lung of a manikin, decrease of the oxygen saturation was measured over 20 min for each method.
Results
Oxygen saturation in the test lung dropped from 97 ± 1% (baseline in all groups) to 58 ± 3% in the control-group (p < 0.001 compared to all other groups) and to 78 ± 1% in the nasal prong group (p < 0.001 compared to all other groups). Oxygen saturation remained at 95 ± 2% in both the OOD group and the bronchoscopy group (p = 0.451 between those two groups).
Conclusion
Simulating apneic laryngeal oxygenation in a preoxygenated manikin, both oxygen insufflation via the OOD and the bronchoscope kept oxygen saturation in the test lung at 95% over 20 min. Both methods significantly were more effective than oxygen insufflation via nasal prongs.
Publisher
Springer Science and Business Media LLC
Subject
Anesthesiology and Pain Medicine
Reference23 articles.
1. Mort TC. Complications of emergency tracheal intubation: immediate airway-related consequences: part II. J Intensive Care Med. 2007;22(4):208–15.
2. Abdellatif AA, Ali MA. GlideScope videolaryngoscope versus flexible fiberoptic bronchoscope for awake intubation of morbidly obese patient with predicted difficult intubation. Middle East J Anaesthesiol. 2014;22(4):385–92.
3. Kramer A, Muller D, Pfortner R, Mohr C, Groeben H. Fibreoptic vs videolaryngoscopic (C-MAC((R)) D-BLADE) nasal awake intubation under local anaesthesia. Anaesthesia. 2015;70(4):400–6.
4. Mendonca C, Mesbah A, Velayudhan A, Danha R. A randomised clinical trial comparing the flexible fibrescope and the Pentax airway scope (AWS)((R)) for awake oral tracheal intubation. Anaesthesia. 2016;71(8):908–14.
5. Vourc'h M, Huard D, Feuillet F, Baud G, Guichoux A, Surbled M, et al. Preoxygenation in difficult airway management: high-flow oxygenation by nasal cannula versus face mask (the PREOPTIDAM study). Protocol for a single-centre randomised study. BMJ Open. 2019;9(4):e025909.
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献