Validity of simplified, calibration-less exercise intensity measurement using resting heart rate during sleep: a method-comparison study with respiratory gas analysis

Author:

Matsuura Hirotaka,Mukaino MasahikoORCID,Otaka Yohei,Kagaya Hitoshi,Aoshima Yasushi,Suzuki Takuya,Inukai Ayaka,Hattori Emi,Ogasawara Takayuki,Saitoh Eiichi

Abstract

Abstract Background The recent development of wearable devices has enabled easy and continuous measurement of heart rate (HR). Exercise intensity can be calculated from HR with indices such as percent HR reserve (%HRR); however, this requires an accurate measurement of resting HR, which can be time-consuming. The use of HR during sleep may be a substitute that considers the calibration-less measurement of %HRR. This study examined the validity of %HRR on resting HR during sleep in comparison to percent oxygen consumption reserve (%VO2R) as a gold standard. Additionally, a 24/7%HRR measurement using this method is demonstrated. Methods Twelve healthy adults aged 29 ± 5 years underwent treadmill testing using the Bruce protocol and a 6-min walk test (6MWT). The %VO2R during each test was calculated according to a standard protocol. The %HRR during each exercise test was calculated either from resting HR in a sitting position (%HRRsitting), when lying awake (%HRRlying), or during sleep (%HRRsleeping). Differences between %VO2R and %HRR values were examined using Bland-Altman plots. A 180-day, 24/7%HRR measurement with three healthy adults was also conducted. The %HRR values during working days and holidays were compared. Results In the treadmill testing, the mean difference between %VO2R and %HRRsleeping was 1.7% (95% confidence interval [CI], − 0.2 to 3.6%). The %HRRsitting and %HRRlying values were 10.8% (95% CI, 8.8 to 12.7%) and 7.7% (95% CI, 5.4 to 9.9%), respectively. In the 6MWT, mean differences between %VO2R and %HRRsitting, %HRRlying and %HRRsleeping were 12.7% (95% CI, 10.0 to 15.5%), 7.0% (95% CI, 4.0 to 10.0%) and − 2.9% (95% CI, − 5.0% to − 0.7%), respectively. The 180-day, 24/7%HRR measurement presented significant differences in %HRR patterns between working days and holidays in all three participants. Conclusions The results suggest %HRRsleeping is valid in comparison to %VO2R. The results may encourage a calibration-less, 24/7 measurement model of exercise intensity using wearable devices. Trial registration UMIN000034967. Registered 21 November 2018 (retrospectively registered).

Publisher

Springer Science and Business Media LLC

Subject

Rehabilitation,Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3