Digital assessment of the accuracy of implant impression techniques in free end saddle partially edentulous patients. A controlled clinical trial

Author:

Dohiem Mohamed M.,Abdelaziz Medhat Sameh,Abdalla Mohamed Farouk,Fawzy Aya Mohamed

Abstract

Abstract Objectives This in vivo study aims to assess the accuracy of the digital intraoral implant impression technique, the conventional closed-tray impression technique, and open-tray impression techniques in a standardized method of data segmentation along with the best-fit algorithm to overcome the inconsistency of results of previous studies regarding implant impression techniques. Materials and methods Sixteen implants were placed in eight patients. Each patient has undergone four impression techniques: direct intraoral scanning of the stock abutment, intraoral scanning using a scan body, conventional closed tray impression technique, and the conventional open tray impression technique. The conventional impressions were poured into stone casts with analogues and stock abutments and scanned using a desktop scanner. In intraoral scanning of the scan body, computer-aided design software was used for the replacement of the scan body with a custom-made abutment that is identical to the stock abutment, allowing comparison with the other impression techniques. The deviation in implant position between the groups was measured using special 3D inspection and metrology software. Statistical comparisons were carried out between the studied groups using a one-way analysis of variance (ANOVA) test. Results The total deviation between groups was compared to the reference group represented by the intraoral scanning of the abutment. The total deviation was statistically significantly different (P = 0.000) among the different studied groups. The mean deviation was recorded as 21.45 ± 3.3 μm, 40.04 ± 4.1 μm, and 47.79 ± 4.6 μm for the intraoral scanning of the scan body, the conventional closed, and open tray, respectively. Conclusion For implant impressions in partially edentulous patients, intraoral oral scanning using a scan body significantly improves scanning and overall accuracy. Regarding conventional impressions, the closed-tray impression techniques showed more accuracy than conventional open-tray impressions. Clinical relevance Intraoral digital implant impression using scan body offers more accuracy than conventional implant impression techniques for recording posterior implant position in free-end saddle partially edentulous patients.

Funder

The Science, Technology & Innovation Funding Authority

Publisher

Springer Science and Business Media LLC

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3