Author:
Elashry Wafaa Youssef,Elsheikh Mohamed Maamoun,Elsheikh Ali Mohamed
Abstract
Abstract
Background
This clinical study aims to evaluate the accuracy of the conventional implant impression techniques compared to the digital impression ones in bilateral distal extension cases.
Methods
A total of 32 implants were placed in eight patients missing all mandibular posterior teeth except the first premolars. Each patient received a total of four implants, with two implants placed on each side, in order to provide support for three units of screw-retained zirconia restorations. Following osteointegration, the same patient underwent two implant-level impression techniques: Conventional open-tray impressions CII (splinted pick-up) and digital implant impressions DII with TRIOS 3 Shape intraoral scanner. The accuracy of impressions was evaluated utilizing a three-dimensional superimposition analysis of standard tessellation language (STL) files. Subsequently, the scan bodies were segmented using Gom inspect software to measure three-dimensional deviations in a color-coding map. Data were statistically analyzed using the Kruskal Wallis test and then a post-hoc test to determine the significance level (P < 0.05).
Results
The study revealed that higher angular and positional deviations were shown toward distal scan bodies compared to mesial ones for both impression techniques. However, this difference was not statistically significant (P > 0.05).
Conclusion
Splinted open-tray conventional impression and intraoral scanning implant impression techniques have demonstrated comparable accuracy.
Trial registration
Clinical Trials.gov Registration ID NCT05912725. Registered 22/06/ 2023- Retrospectively registered, https://register.clinicaltrials.gov.
Publisher
Springer Science and Business Media LLC
Reference32 articles.
1. Srinivasan M, Meyer S, Mombelli A, Müller F. Dental implants in the elderly population: a systematic review and meta-analysis. Clin Oral Implants Res. 2017;28:920–30.
2. de França DG, Morais MH, das Neves FD, Barbosa GA. Influence of CAD/CAM on the fit accuracy of implant-supported zirconia and cobalt-chromium fixed dental prostheses. J Prosthet Dent. 2015;113:22–8.
3. Karl M, Graef F, Schubinski P, Taylor T. Effect of intraoral scanning on the passivity of fit of implant-supported fixed dental prostheses. Quintessence Int. 2012;43:555–62.
4. Gallucci GO, Papaspyridakos P, Ashy LM, Kim GE, Brady NJ, Weber HP. Clinical accuracy outcomes of closed-tray and open-tray implant impression techniques for partially edentulous patients. Int J Prosthodont. 2011;24:469–72.
5. Schmidt A, Rein PE, Wöstmann B, Schlenz MA. A comparative clinical study on the transfer accuracy of conventional and digital implant impressions using a new reference key-based method. Clin Oral Implants Res. 2021;32:460–9.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献