Effects of exercise during water immersion on arterial function in humans

Author:

Carter Howard H.1ORCID,Cheng Jem L.2ORCID,MacDonald Maureen J.2ORCID,Pienaar Oliver1ORCID,Coleman Alexander1,Naylor Louise H.1ORCID,Green Daniel J.1ORCID

Affiliation:

1. School of Human Sciences, The University of Western Australia, Crawley, Western Australia, Australia

2. Department of Kinesiology, McMaster University, Hamilton, Ontario, Canada

Abstract

Flow-mediated dilation (FMD) provides a valid bioassay of vascular function in humans. Although water immersion induces hemodynamic effects that modify brachial artery shear stress, it is unclear whether water-based exercise modifies FMD. We hypothesized that exercise in 32°C water would decrease brachial artery shear and FMD relative to land-based exercise, whereas exercise in 38°C would increase brachial shear and FMD. Ten healthy participants (8 males; 23.9 ± 3.3 yr) completed 30 min of resistance-matched cycle exercise in three separate conditions: on land and in 32°C and 38°C water. Brachial artery shear rate area under the curve (SRAUC) was measured throughout each condition, with FMD measured pre- and postexercise. Brachial SRAUC increased during exercise in all conditions and was highest across the 38°C condition compared with Land and 32°C conditions (38°C: 27,507 ± 8,350 vs. Land: 9,908 ± 4,738 vs. 32°C: 13,840 ± 5,861 1/s, P < 0.001). Retrograde diastolic shear was greater during 32°C than both Land and 38°C conditions (32°C:−3,869 ± 2,198 vs. Land:−1,602 ± 1,334 vs. 32°C:−1,036 ± 1,754, P < 0.01). FMD increased as a result of 38°C (6.2 ± 1.9 vs. 8.5 ± 2.7%, P = 0.03), with no change in the Land exercise (6.3 ± 2.4 vs. 7.7 ± 2.4%, P = 0.10) or 32°C condition (6.4 ± 3.2 vs. 6.7 ± 3.2%, P = 0.99). Our findings indicate that cycle exercise in hot water attenuates retrograde shear, increases antegrade shear, and FMD. Exercise in 32°C water induces central hemodynamic changes relative to land-based exercise, but these do not translate to increases in FMD in either condition, likely due to the impact of increased retrograde shear. Our findings indicate that modification of shear has direct acute impacts on endothelial function in humans.

Funder

Gouvernement du Canada | Natural Sciences and Engineering Research Council

US | USN | ONR | Office of Naval Research Global

Australia Defence Science and Technology Group

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献