Impact of Introducer Sheath Coating on Endothelial Function in Humans After Transradial Coronary Procedures

Author:

Dawson Ellen A.1,Rathore Sudhir1,Cable N. Timothy1,Wright D. Jay1,Morris John L.1,Green Daniel J.1

Affiliation:

1. From the Research Institute for Sport and Exercise Sciences (E.A.D., N.T.C., D.J.G.), Liverpool John Moores University, and Liverpool Heart and Chest Hospital (S.R., D.J.W., J.L.M.), Liverpool, England, and School of Sport Science, Exercise and Health (D.J.G.), University of Western Australia, Western Australia, Australia.

Abstract

Background— The aim of this study was to compare the impact of transradial catheterization with hydrophilic-coated catheter sheaths versus uncoated sheaths on NO-mediated endothelial-dependent and -independent vasodilator function. Methods and Results— Thirty-five subjects undergoing transradial catheterization were recruited and assessed before and the day after catheterization. A subgroup was also assessed 3 to 4 months after catheterization. Subjects received hydrophilic-coated sheaths (n=15) or uncoated sheaths (n=20). Radial artery flow-mediated dilatation and endothelium- and NO-dependent arterial dilatation were assessed within the region of sheath placement. Glyceryl trinitrate endothelium-independent NO-mediated function was also assessed. The noncatheterized arm provided an internal control. Flow-mediated dilatation in the catheterized arm decreased from 10.3�3.8% to 5.3�3.3% and 8.1�2.4% to 5.2�3.7% in the coated and uncoated groups, respectively ( P <0.01). These values returned toward baseline levels ≈3 months later (coated, 6.4�1.4%; uncoated, 9.4�4.1%; P <0.05) versus postprocedure. Glyceryl trinitrate decreased from 14.8�7.2% to 9.5�4.1% ( P <0.05) in the coated group and from 12.2�4.6% to 7.5�4.2% ( P <0.01) in the uncoated group. Values returned to baseline at ≈3 months (coated, 16.6�5.6%; uncoated, 12.1�3.9%; P <0.05). There was no difference in the magnitude of decrease in flow-mediated dilatation or glyceryl trinitrate between coated and uncoated groups. No changes in function occurred in the noncatheterized arm. Conclusions— Placement of a catheter sheath inside the radial artery disrupts vasodilator function, which recovers after 3 months. No differences were evident between hydrophilic-coated and uncoated sheaths.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3