V-A and A-V modes in whole body and regional kinetics: domain of validity from a physiological model

Author:

Sacca L.1,Toffolo G.1,Cobelli C.1

Affiliation:

1. Department of Internal Medicine, Federico II University, Second Schoolof Medicine, Naples, Italy.

Abstract

In turnover studies, both at whole body and regional level, sources of tracer and tracee are in general nonidentical thus resulting in nonuniformity of specific activity (SA). Guidelines are available in literature to deal with the heterogeneous SA problem, and either the V-A or A-V modes, based on the arterial and mixed venous blood SA, respectively, have been recommended for different substrates. In particular, the A-V mode is considered the method of choice for studying lactate, amino acids, free fatty acid, etc. Guidelines are based on specific models chosen to describe kinetic and circulatory events of the substance under study but are often conflicting. A unitary physiological framework to understand assumptions of various models is also lacking. In this paper, we first review these models to assess their domain of validity. In particular, we point out major drawbacks that relate to the tissue compartment being treated as a lumped well-mixed pool with a single SA value. We then attempt to handle the nonuniform tissue SA by employing a more physiological model. The tissue system is thought to be made up of elementary units connected in parallel and categorized according to their functional ability to affect incoming SA. Potential changes of SA within individual units are examined. Thus each tissue unit may provide a different contribution to the overall change in SA, as measured in mixed venous blood. A spatial profile of SA is also identified both along the direction of blood flow and transversely toward the inner cellular space. This distributed model allows assessment of the domain of validity of V-A and A-V modes. We show that, in general, the V-A mode underestimates the production rate both at whole body and regional level, whereas the A-V mode can either under- or overestimate it.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology,Endocrinology, Diabetes and Metabolism

Cited by 24 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3