Alternative diastolic function models of ventricular longitudinal filling velocity are mathematically identical

Author:

Bhagavan Druv1,Padovano William M.1,Kovács Sándor J.1

Affiliation:

1. Cardiovascular Biophysics Laboratory, Cardiovascular Division, Department of Medicine, Washington University School of Medicine, St. Louis, Missouri

Abstract

The spatiotemporal features of normal in vivo cardiac motion are well established. Longitudinal velocity has become a focus of diastolic function (DF) characterization, particularly the tissue Doppler e′-wave, manifesting in early diastole when the left ventricle (LV) is a mechanical suction pump (dP/dV < 0). To characterize DF and elucidate mechanistic features, several models have been proposed and have been previously compared algebraically, numerically, and in their ability to fit physiological velocity data. We analyze two previously noncompared models of early rapid-filling lengthening velocity (Doppler e′-wave): parametrized diastolic filling (PDF) and force balance model (FBM). Our initial numerical experiments sampled FBM-generated e′( t) contours as input to determine PDF model predicted fit. The resulting exact numerical agreement [standard error of regression (SER) = 9.06 × 10−16] was not anticipated. Therefore, we analyzed all published FBM-generated e′( t) contours and observed identical agreement. We re-expressed FBM’s algebraic expressions for e′( t) and observed for the first time that model-based predictions for lengthening velocity by the FBM and the PDF model are mathematically identical: e′( t) = γe−α tsinh(β t), thereby providing exact algebraic relations between the three PDF parameters and the six FBM parameters. Previous pioneering experiments have independently established the unique determinants of e′( t) to be LV relaxation, restoring forces (stiffness), and load. In light of the exact intermodel agreement, we conclude that the three PDF parameters, relaxation, stiffness (restoring forces), and load, are unique determinants of DF and e′( t). Thus, we show that only the PDF formalism can compute the three unique, independent, physiological determinants of long-axis LV myocardial velocity from e′( t). NEW & NOTEWORTHY We show that two separate, independently derived physiological (kinematic) models predict mathematically identical expressions for LV-lengthening velocity (Doppler e′-wave), indicating that damped harmonic oscillatory motion is a physiologically accurate model of diastolic function. Although both models predict the same “overdamped” velocity contour, only one model solves the “inverse problem” and generates unique, lumped parameters of relaxation, stiffness (restoring force), and load from the e′-wave.

Funder

Alan A. and Edith L. Wolff Charitable Trust

Foundation for Barnes-Jewish Hospital

NIH MSTP T32 Training Grant

Publisher

American Physiological Society

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine,Physiology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3