Assessment and consequences of the constant-volume attribute of the four-chambered heart

Author:

Bowman Andrew W.1,Kovács Sándor J.1

Affiliation:

1. Cardiovascular Biophysics Laboratory and Cardiovascular MR Laboratories, Cardiovascular Division, Washington University School of Medicine, St. Louis, Missouri 63110

Abstract

The constant-volume hypothesis regarding the four-chambered heart states that total pericardial volume remains invariant throughout the cardiac cycle. Previous canine studies have indicated that the pericardial volume remains constant within 5%; however, this hypothesis has not been validated in humans using state-of-the-art technology. The constant-volume hypothesis has several predictable functional consequences, including a relationship between atrial ejection fraction and chamber equilibrium volumes. Using cardiac magnetic resonance (MR) imaging (MRI), we measured the extent to which the constant-volume attribute of the heart is valid, and we tested the accuracy of the predicted relationship between atrial ejection fraction and chamber equilibrium volumes. Eleven normal volunteers and one volunteer with congenital absence of the pericardium were imaged using a 1.5-T MR scanner. A short-axis cine-loop stack covering the entire heart was acquired. The cardiac cycle was divided into 20 intervals. For each slice and interval, pericardial volumes were measured. The slices were stacked and summed, and total pericardial volume as a function of time was determined for each subject. In the normal subjects, chamber volumes at ventricular end diastole, end systole, and diastasis were measured. Pericardial volume remained invariant within 5 ± 1% in normal subjects; maximum variation occurred near end systole. In the subject with congenital absence of the pericardium, total heart volume, defined by the epicardial surface, varied by 12%. The predictions of the relationship between atrial ejection fraction and chamber equilibrium volumes were well fit by MRI data. In normal subjects, the four-chambered heart is a constant-volume pump within 5 ± 1%, and constant-volume-based modeling accurately predicts previously unreported physiological relationships.

Publisher

American Physiological Society

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine,Physiology

Cited by 63 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3