CORP: Standardizing methodology for assessing spontaneous baroreflex control of muscle sympathetic nerve activity in humans

Author:

Holwerda Seth W.1,Carter Jason R.2,Yang Huan3,Wang Jing4,Pierce Gary L.5,Fadel Paul J.6

Affiliation:

1. Department of Anesthesiology, University of Kansas Medical Center, Kansas City, Kansas

2. Department of Health and Human Development, Montana State University, Bozeman, Montana

3. Department of Neurology, Beth Israel Deaconess Medical Center/Harvard Medical School, Boston, Massachusetts

4. College of Nursing, University of Texas at Arlington, Arlington, Texas

5. Department of Health and Human Physiology, University of Iowa, Iowa City, Iowa

6. Department of Kinesiology, University of Texas at Arlington, Arlington, Texas

Abstract

The use of spontaneous bursts of muscle sympathetic nerve activity (MSNA) to assess arterial baroreflex control of sympathetic nerve activity has seen increased utility in studies of both health and disease. However, methods used for analyzing spontaneous MSNA baroreflex sensitivity are highly variable across published studies. Therefore, we sought to comprehensively examine methods of producing linear regression slopes to quantify spontaneous MSNA baroreflex sensitivity in a large cohort of subjects ( n = 150) to support a standardized procedure for analysis that would allow for consistent and comparable results across laboratories. The primary results demonstrated that 1) consistency of linear regression slopes was considerably improved when the correlation coefficient was above −0.70, which is more stringent compared with commonly reported criterion of −0.50, 2) longer recording durations increased the percentage of linear regressions producing correlation coefficients above −0.70 (1 min = 15%, 2 min = 28%, 5 min = 53%, 10 min = 67%, P < 0.001) and reaching statistical significance (1 min = 40%, 2 min = 69%, 5 min = 78%, 10 min = 89%, P < 0.001), 3) correlation coefficients were improved with 3-mmHg versus 1-mmHg and 2-mmHg diastolic blood pressure (BP) bin size, and 4) linear regression slopes were reduced when the acquired BP signal was not properly aligned with the cardiac cycle triggering the burst of MSNA. In summary, these results support the use of baseline recording durations of 10 min, a correlation coefficient above −0.70 for reliable linear regressions, 3-mmHg bin size, and importance of properly time-aligning MSNA and diastolic BP. Together, these findings provide best practices for determining spontaneous MSNA baroreflex sensitivity under resting conditions for improved rigor and reproducibility of results.

Funder

American Heart Association

HHS | NIH | National Heart, Lung, and Blood Institute

HHS | NIH | National Center for Advancing Translational Sciences

HHS | NIH | National Institute on Alcohol Abuse and Alcoholism

Publisher

American Physiological Society

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine,Physiology

Cited by 23 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3