Radiation monitoring of non-lead-lined treatment room in general pediatric ward and adjacent areas for high dose 131Iodine-mIBG

Author:

Chuamsaamarkkee Krisanat1,Charoenphun Putthiporn1,Kamwang Natthaporn2,Monthonwattana Sahakan2,Changmuang Wirote1,Thongklam Kittiphong1,Kositwattanarerk Arpakorn1,Anongpornjossakul Yoch1,Chamroonrat Wichana1,Sritara Chanika1

Affiliation:

1. Department of Diagnostic and therapeutic Radiology, Faculty of Medicine , Ramathibodi Hospital , Mahidol University , Thailand 10400

2. Thailand Institute of Nuclear Technology (Public Organization), Nakornnayok, Thailand 26120

Abstract

Abstract Background: 131I-metaiodobenzylguanidine (mIBG) offers an effectively targeted radionuclide therapy in pediatric patients. According to radiation protection authority in our country, the patient treated with high-dose (>1100 MBq) radioiodine is recommended to stay in the hospital. Hence, this study intends to measure the radiation exposure in nonlead-lined treatment room installing with portable lead shields located in general pediatric ward and surrounding areas. In addition, this study also aims to measure the radiation exposure to the family caregiver in pediatric patients received high dose 131I-mIBG. Methods: Environmental OSL (optically stimulated luminescence) monitoring devices (InLight®, Al2O3:C) were prepared and calibrated by Thailand Institute of Nuclear Technology (TINT). Twenty-five set of OSLs were placed in and surrounded the treatment room. Dose to family caregiver was recorded by digital semiconductor dosimeter (ALOKA PDM-112) also calibrated by TINT. The measurement was carried for four pediatric patients treated with 131IMIBG (activity 3700 – 5500 MBq). Results: The ambient doses equivalent and the dose rate were analyzed, the limit of 10 and 0.5 μSv/h are accepted for radiation worker and member of the public, respectively. The dose rate around the patient bed and toilet were high as expected. Dose rates at the wall of adjacent room and corridor were slightly greater than the public limit (range 1.82 to 4.48 μSv/h). Remarkably, the dose rates at caregiver chair (outside the shielding) were exceeded the limits (30.57 ± 5.69 μSv/h). Consequently, this was correlated with high personal dose equivalent to family caregivers which listed as 175, 1632, 6760 and 7433 μSv for the patient age of 15, 5, 1 and 1 year respectively. Conclusion: These radiation monitoring data provided the important information to manage radiation protection and aware of radiation exposure when using non-lead-lined treatment room in general pediatric ward.

Publisher

Walter de Gruyter GmbH

Reference13 articles.

1. [1] Markelewicz Jr RJ, Lorenzen WA, Shusterman S, et al. Radiation exposure to family caregivers and nurses of pediatric neuroblastoma patients receiving 131i-metaiodobenzylguanidine (131i-mIBG) therapy. Clin Nucl Med. 2013;38(8):604-607.10.1097/RLU.0b013e31829af3c8

2. [2] Tonnonchiang S, Sritongkul N, Chaudakshetrin P, Tuntawiroon M. Radiation exposure to relatives of patients treated with iodine-131 for thyroid cancer at Siriraj hospital. J Med Assoc Thai. 2016;99(2):220-224.

3. [3] Gains JE, Walker C, Sullivan T, et al. Radiation exposure to comforters and carers during paediatric molecular radiotherapy. Pediatr Blood Cancer. 2015;62(2):235-239.10.1002/pbc.25250

4. [4] Cougnenc O, Defachelles A-S, Carpentier P, et al. High-dose 131i-mibg therapies in children: Feasibility, patient dosimetry and radiation exposure to workers and family caregivers. Radiat Prot Dosimetry. 2017;173(4):395-404.

5. [5] de la Guardia M, Mata S, McCammon S, et al. Physician and nursing personnel radiation exposure monitoring experience during the first year of performing i-131 metaiodobenzylguanidine (mIBG) therapy. Conference: Society of Nuclear Medicine and Molecular Imaging, Baltimore, MD. J Nucl Med. 2015;56(Supplement3):1251.

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献