Surface finishing of unused rotary endodontic instruments: a SEM study

Author:

Chianello Giovani1,Specian Vivyane Leal1,Hardt Lilian Cristina Fucuda1,Raldi Denise Pontes1,Lage-Marques José Luiz1,Habitante Sandra Márcia1

Affiliation:

1. University of Taubaté, Brazil

Abstract

During endodontic therapy, cleaning of root canals is performed using endodontic files and auxiliary chemical substances, and it is important that the endodontist be familiar with the instruments used in daily practice. This study evaluated, under scanning electron microscopy (SEM), the quality of the surface finishing of unused rotary endodontic instruments. Fifty sizes 20, 25 and 30 rotary files from different commercial brands (ProFile, Protaper, Race, Hero and K3 Endo) were removed directly from their packages and had their final 3 mm examined with a scanning electron microscope at x190 magnification with no previous preparation. The images were evaluated by 3 skillful, calibrated, blinded observers according to the following criteria: cutting edge, debris, grooves, microcavities, tip shape, tip position, scraping and transition angle. Data were recorded in worksheets designed for the study. Irregular edges were observed in 50-100% of the files. Except for ProFile, all commercial brands presented surface debris in 100% of samples. Only Race files showed no grooves or microcavities. K3 Endo files presented the best tip centralization. Excetp for ProTaper files, all commercial brands presented blunt-cutting edges in 100% of samples. All types of files presented surface scraping. K3 Endo files and Protaper had a high percentage of transition angle. Based on the evaluation criteria used in the present study, most samples presented a minimum of 2 alterations and a maximum of 7 alterations per instrument. Under the tested conditions, the quality of the surface finishing of the examined instruments was not as expected, given that no instrument was free of imperfections and most of them presented at least 2 and up to 7 types of surface defects. These results suggest that the manufacturing process and the packaging conditions of rotary endodontic instruments are far from ideal.

Publisher

FapUNIFESP (SciELO)

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3