Influence of cervical preflaring on apical file size determination in maxillary lateral incisors

Author:

Ibelli Guilherme Siqueira1,Barroso Juliana Machado1,Capelli Alexandre1,Spanó Júlio César Emboava1,Pécora Jesus Djalma1

Affiliation:

1. University of São Paulo

Abstract

The purpose of this study was to investigate the influence of cervical preflaring on determination of the initial apical file in maxillary lateral incisors. Forty human lateral incisors with complete root formation were used. After standard access cavities, a size 06 K-file was inserted into each canal until the apical foramen was reached. The WL (WL) was set 1 mm short of the apical foramen. Four groups (n=10) were formed at random, according to the type of cervical preflaring performed. Group 1 received the initial apical instrument without previous preflaring of the cervical and middle root canal thirds. Group 2 had the cervical and middle root canal thirds enlarged with nickel-titanium Orifice Opener instruments. Group 3 had the cervical and middle root canal thirds enlarged with Gates-Glidden drills. Titanium-nitrite treated, stainless steel LA Axxess burs were used for preflaring the cervical and middle root canal thirds of group 4. Each canal was sized using manual K-files, starting with size 08 files with passive movements until the WL was reached. File sizes were increased until a binding sensation was felt at the WL, and the instrument size was recorded for each tooth. The apical region was then observed under a stereoscopic magnifier, images were recorded digitally and the differences between root canal and maximum file diameters were recorded (in mm) for each sample. Significant differences were found between the groups regarding the anatomical diameter at the WL and the first file to bind the canal (p = 0.01). The major discrepancy was found when no preflaring was performed (0.1882 mm average). Canals preflared with Orifice Opener instruments (0.0485 mm average) and Gates-Glidden drills (0.1074 mm average) also showed great discrepancy. The LA Axxess burs produced the smallest differences between anatomical diameter and first file to bind (0.0119 mm average). Instrument binding technique for determining anatomical diameter at WL was not accurate. Preflaring of the cervical and middle thirds of the root canal improved anatomical diameter determination; the instrument used for preflaring played a major role on determination of the anatomical diameter at the WL. Canals preflared with LA Axxess burs created a more accurate relationship between file size and anatomical diameter.

Publisher

FapUNIFESP (SciELO)

Subject

General Dentistry

Reference16 articles.

1. Endodontic Practice;Grossman LI,1988

2. Endodontics;Ingle JI,1994

3. Passive step-back technique;Torabinejad M;Oral Surg Oral Med Oral Pathol,1994

4. Principles and Practice of Endodontics;Walton RE,1996

5. Canal orifice enlargement as related to biomechanical preparation;Leeb J;J Endod,1983

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3