Insulin infusion sets associated with adverse events: strategies for improved diabetes education

Author:

Neves Ana Lucia Domingues,Martins Luiz Eduardo Galvão,Gabbay Mônica Andrade Lima,Pascali Paula,de Oliveira Tiago,Martinazzo Aldo,Dib Sérgio Atala,Casarini Dulce Elena,Aredes Sebastião Vagner,Tenorio Fernanda Silva,Cunha Tatiana Sousa

Abstract

IntroductionInsulin Infusion Sets (IIS) play a crucial role in ensuring the safe delivery of insulin through a Continuous Subcutaneous Insulin Infusion (CSII) for individuals with Type 1 Diabetes (T1D). Recent advancements in therapy have highlighted the need to address issues such as unexplained hyperglycemia and IIS occlusion.ObjectiveTo investigate the adverse events (AEs) associated with IIS that impact the treatment of T1D, with a specific focus on promoting effective educational practices.MethodsOne hundred and eighteen patients under treatment at the Diabetes Center Insulin Pump Ambulatory, Federal University of São Paulo responded to a semi-structured questionnaire. Over 6 months, a nurse researcher interviewed them via video calls.ResultsCatheter-related adverse events (AEs) included catheter knots, folding, and accidental traction. AEs associated with cannula use were mainly related to cannula fixation adhesive, insulin leakage, bleeding episodes, and skin problems. The cannula patch tends to detach easily in hot conditions or when used for more than 3 days, leading to local itching. Adhesive glue can cause redness and pain. Insulin leakage typically occurs after the catheter disconnects from the cannula, accidental cannula traction, or beneath the cannula patch. Bleeding has been reported inside the cannula or at the insertion site, resulting in local pain and, in some cases, obstruction of insulin flow. When accidental cannula traction occurs, it is recommended to replace the entire IIS system. In situations involving bleeding, leakage, insulin odor, or unsuccessful attempts to correct hyperglycemic episodes with a “bolus” of insulin, it is advisable to change the IIS system and evaluate appropriate techniques for handling and infusing the device. Moreover, regular inspections of the device and reservoir/cartridge are essential.ConclusionSerious AEs can occur even in cases where the occlusion alarm is not activated, leading to interruptions in insulin flow. Conversely, in less severe situations, alarm activation can occur even in the absence of insulin flow interruption. Accidental catheter traction and catheter bending are commonly encountered in everyday situations, while issues related to the cannula directly affect blood glucose levels. AEs related to the IIS cannula often involve insulin leakage into the skin, bleeding, and skin events attributed to adhesive issues with the cannula.

Publisher

Frontiers Media SA

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3