Insulin Pump Risks and Benefits: A Clinical Appraisal of Pump Safety Standards, Adverse Event Reporting, and Research Needs

Author:

Heinemann Lutz1,Fleming G. Alexander2,Petrie John R.3,Holl Reinhard W.4,Bergenstal Richard M.5,Peters Anne L.6

Affiliation:

1. Science & Co, Düsseldorf, Germany

2. Kinexum, Harpers Ferry, WV

3. Institute of Cardiovascular and Medical Sciences, University of Glasgow, Glasgow, UK

4. Institute of Epidemiology and Medical Biometry, ZIBMT, University of Ulm, Ulm, Germany

5. International Diabetes Center at Park Nicollet, Minneapolis, MN

6. Keck School of Medicine of the University of Southern California, Los Angeles, CA

Abstract

Insulin pump therapy, also known as continuous subcutaneous insulin infusion (CSII), is an important and evolving form of insulin delivery, which is mainly used for people with type 1 diabetes. However, even with modern insulin pumps, errors of insulin infusion can occur due to pump failure, insulin infusion set (IIS) blockage, infusion site problems, insulin stability issues, user error, or a combination of these. Users are therefore exposed to significant and potentially fatal hazards: interruption of insulin infusion can result in hyperglycemia and ketoacidosis; conversely, delivery of excessive insulin can cause severe hypoglycemia. Nevertheless, the available evidence on the safety and efficacy of CSII remains limited. The European Association for the Study of Diabetes (EASD) and the American Diabetes Association (ADA) have therefore joined forces to review the systems in place for evaluating the safety of pumps from a clinical perspective. We found that useful information held by the manufacturing companies is not currently shared in a sufficiently transparent manner. Public availability of adverse event (AE) reports on the US Food and Drug Administration’s Manufacturer and User Facility Device Experience (MAUDE) database is potentially a rich source of safety information but is insufficiently utilized due to the current configuration of the system; the comparable database in Europe (European Databank on Medical Devices [EUDAMED]) is not publicly accessible. Many AEs appear to be attributable to human factors and/or user error, but the extent to which manufacturing companies are required by regulators to consider the interactions of users with the technical features of their products is limited. The clinical studies required by regulators prior to marketing are small and over-reliant on bench testing in relation to “predicate” products. Once a pump is available on the market, insufficient data are made publicly available on its long-term use in a real-world setting; such data could provide vital information to help health care teams to educate and support users and thereby prevent AEs. As well as requiring more from the manufacturing companies, we call for public funding of more research addressing clinically important questions in relation to pump therapy: both observational studies and clinical trials. At present, there are significant differences in the regulatory systems between the US and European Union at both pre- and postmarketing stages; improvements in the European system are more urgently required. This statement concludes with a series of recommended specific actions for “meknovigilance” (i.e., a standardized safety approach to technology) that could be implemented to address the shortcomings we highlight.

Publisher

American Diabetes Association

Subject

Advanced and Specialized Nursing,Endocrinology, Diabetes and Metabolism,Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3