Efficacy of pipeline embolization device vs. traditional coils in embolization of intracranial aneurysms: A systematic review and meta-analysis

Author:

Li Wei,Xiao Zaixing,Zhao Kaixuan,Yang Shijie,Zhang Yichuan,Li Bin,Zhou Yu,Ma Yong,Chai Erqing

Abstract

IntroductionIn recent years, the Pipeline embolization device (PED) has been widely used in the embolization of intracranial aneurysms, but there are some inconsistent findings on whether its efficacy and safety are superior to those of traditional coils embolization (coils alone, stent-assisted coils and balloon-assisted coils). The purpose of this meta-analysis was to evaluate the safety and efficacy of PED in intracranial aneurysm embolization by comparing with traditional coils.MethodsWe systematically searched PubMed, Embase, Web of Science, and The Cochrane Library databases for randomized controlled trials and observational studies (case-control studies and cohort studies) comparing the efficacy of PED with traditional coils in intracranial aneurysm embolization published before April 1, 2022. The endpoints observed in this meta-analysis were procedure-related intracranial hemorrhage, procedure-related intracranial ischemia, other procedure-related complications (e.g., aneurysm rupture, neurological impairment, etc.), retreatment rate, complete occlusion (100%) of the aneurysm at the last follow-up, and favorable functional outcome (MRS ≤ 2).ResultsA total of 10 studies with a total of 1,400 patients (PED group: 576 and Traditional coils: 824) were included in this meta-analysis. A comprehensive analysis of the included literature showed that the PED group had a higher rate of complete aneurysm occlusion [OR = 2.62, 95% Cl (1.94, 3.55), p < 0.00001] and Lower re-treatment rate [OR = 0.20, 95% Cl (0.12, 0.34 p < 0.00001)] compared with the traditional coil embolization group at the last follow-up. In terms of procedure-related intracranial hemorrhage [OR = 3.04, 95% Cl (1.08, 8.57), p = 0.04] and other procedure-related complications [OR = 2.91, 95% Cl (1.48, 5.57), p = 0.002], the incidence of PED was higher than that of the traditional coil embolization group. Moreover, in terms of favorable functional outcome [OR = 0.4, 95% Cl (0.22, 0.71), p = 0.002] of patients at the last follow-up, the PED group was lower than the traditional coil embolization group. There was no statistically significant between the two groups in terms of surgery-related intracranial ischemia complications [OR = 0.88, 95% Cl (0.47, 1.64), p = 0.68].ConclusionPED had higher rates of complete aneurysm occlusion and lower rates of aneurysm retreatment compared with traditional coils, but traditional coils was superior to the PED group in terms of procedure-related intracranial hemorrhage complication and other procedure-related complications (aneurysm rupture, neurological impairment), and favorable functional outcome (mRS ≤ 2). This result still needs to be further confirmed by additional large-sample, multicenter, prospective randomized controlled trials.Systematic review registrationhttps://www.crd.york.ac.uk/PROSPERO/, identifier: CRD42022325673.

Publisher

Frontiers Media SA

Subject

Neurology (clinical),Neurology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3