Affiliation:
1. Department of Neurological Surgery, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania
Abstract
OBJECTIVE
The object of this study was to compare the efficacy and safety profile of the Pipeline embolization device (PED)/Pipeline Flex embolization device (PED Flex) with that of the Pipeline Flex embolization device with Shield Technology (PED Shield). After introducing the first-generation PED and the second-generation PED Flex with its updated delivery system, the PED Shield was launched with a synthetic layer of phosphorylcholine surface modification to reduce thrombogenicity.
METHODS
This is a retrospective review of unruptured aneurysms treated with PED/PED Flex versus PED Shield between 2017 and 2022 at the authors’ institution. Patients with ruptured aneurysms, adjunctive treatment, failed flow diverter deployment, and prior treatment of the target aneurysm were excluded. Baseline characteristics were collected for all patients, including age, sex, past medical history (hypertension, hyperlipidemia, diabetes mellitus), smoking status, aneurysm location, and aneurysm dimensions (neck, width, height) and morphology (saccular, nonsaccular). The primary outcome was procedural and periprocedural complication rates.
RESULTS
The study cohort comprised 200 patients with 200 aneurysms, including 150 aneurysms treated with the PED/PED Flex and 50 treated with the PED Shield. With respect to intraprocedural and periprocedural complications, length of stay, length of follow-up, and functional outcome at discharge, there was no significant difference between the two cohorts. At the midterm follow-up, the rate of in-stent stenosis (PED/PED Flex: 14.2% vs PED Shield: 14.6%, p = 0.927), aneurysm occlusion (complete occlusion: 79.5% vs 80.5%, respectively; neck remnant: 4.7% vs 12.2%; dome remnant: 15.7% vs 7.3%; p = 0.119), and the need for retreatment (5.3% vs 0%, p = 0.097) were comparable between the two cohorts.
CONCLUSIONS
This study suggests that, as compared to first- and second-generation PED and PED Flex, the third-generation PED Shield offers similar rates of complications, aneurysm occlusion, and in-stent stenosis at the midterm follow-up.
Publisher
Journal of Neurosurgery Publishing Group (JNSPG)
Subject
Genetics,Animal Science and Zoology
Reference31 articles.
1. Current treatment strategies for intracranial aneurysms: an overview;Zhao J,2018
2. Pipeline Flex embolisation device with Shield Technology for the treatment of patients with intracranial aneurysms: periprocedural and 6 month outcomes;Yeomans J,2020
3. Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial;Becske T,2013
4. Surgical or endovascular treatment of MCA aneurysms: an agreement study;Boisseau W,2022
5. International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion;Molyneux AJ,2005