Stent-Assisted Coiling of Intracranial Aneurysms

Author:

Chalouhi Nohra1,Jabbour Pascal1,Singhal Saurabh1,Drueding Ross1,Starke Robert M.1,Dalyai Richard T.1,Tjoumakaris Stavropoula1,Gonzalez L. Fernando1,Dumont Aaron S.1,Rosenwasser Robert1,Randazzo Ciro G.1

Affiliation:

1. From the Department of Neurosurgery, Thomas Jefferson University and Jefferson Hospital for Neuroscience, Philadelphia, PA.

Abstract

Background and Purpose— Self-expanding stents are increasingly used for treatment of complex intracranial aneurysms. We assess the safety and the efficacy of intracranial stenting and determine predictors of treatment outcomes. Methods— A total of 508 patients with 552 aneurysms were treated with Neuroform and Enterprise stents between 2006 and 2011 at our institution. A multivariate analysis was conducted to identify predictors of complications, recanalization, and outcome. Results— Of 508 patients, 461 (91%) were treated electively and 47 (9%) in the setting of subarachnoid hemorrhage. Complications occurred in 6.8% of patients. In multivariate analysis, subarachnoid hemorrhage, delivery of coils before stent placement, and carotid terminus/middle cerebral artery aneurysm locations were independent predictors of procedural complications. Angiographic follow-up was available for 87% of patients at a mean of 26 months. The rates of recanalization and retreatment were, respectively, 12% and 6.4%. Older age, previously coiled aneurysms, larger aneurysms, incompletely occluded aneurysms, Neuroform stent, and aneurysm location were predictors of recanalization. Favorable outcomes were seen in 99% of elective patients and 51% of subarachnoid hemorrhage patients. Patient age, ruptured aneurysms, and procedural complications were predictors of outcome. Conclusions— Stent-assisted coiling of intracranial aneurysms is safe, effective, and provides durable aneurysm closure. Higher complication rates and worse outcomes are associated with treatment of ruptured aneurysms. Stent delivery before coil deployment reduces the risk of procedural complications. Staging the procedure may not improve procedural safety. Closed-cell stents are associated with significantly lower recanalization rates.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3