Stent-Associated Flow Remodeling Causes Further Occlusion of Incompletely Coiled Aneurysms

Author:

Lawson Matthew F.1,Newman William C.2,Chi Yueh-Yun3,Mocco J. D.1,Hoh Brian L.1

Affiliation:

1. Department of Neurosurgery, University of Florida, Gainesville, Florida

2. College of Medicine, University of Florida, Gainesville, Florida

3. Department of Epidemiology and Health Policy Research, University of Florida, Gainesville, Florida

Abstract

Abstract BACKGROUND: Incomplete coil occlusion is associated with increased risk of aneurysm recurrence. We hypothesize that intracranial stents can cause flow remodeling, which promotes further occlusion of an incompletely coiled aneurysm. OBJECTIVE: To study our hypothesis by comparing the follow-up angiographic outcomes of stented and nonstented incompletely coiled aneurysms. METHODS: From January 2006 through December 2009, the senior author performed 324 initial coilings of previously untreated aneurysms, 145 of which were Raymond classification 2 and 3. Follow-up angiographic studies were available for 109 of these aneurysms (75%). Angiographic outcomes for stented vs nonstented incompletely coiled aneurysms were compared. A multivariate analysis was performed to identify factors related to the progression of occlusion at follow-up, with adjustment for aneurysm location, size, neck size, Hunt-Hess grade, stent use, initial Raymond score, packing density, age, sex, and medical comorbidities. RESULTS: Of the 109 aneurysms, 37 were stented and 72 were not stented. With a median follow-up time of 15.4 months, 33 stented aneurysms (89%) progressed to complete occlusion compared with 29 nonstented aneurysms (40%). Recanalization rates were lower in the stented group (8.1%) compared with the nonstented group (37.5%; P < .001). On multivariate analysis, stent use (odds ratio, 18.5; 95% confidence interval, 4.3-76.9) and packing density (odds ratio, 1.093; 95% confidence interval, 1.021-1.170) were significant predictors of the progression of occlusion. Aneurysm size was negatively correlated with the progression of occlusion (odds ratio, 0.844; 95% confidence interval, 0.724-0.983). CONCLUSION: Stent-assisted coiling causes progression of occlusion, possibly by a flow remodeling effect. The odds of progression of occlusion of stent-coiled aneurysms were 18.5 times that of nonstented aneurysms.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3