Abstract
UV-Vis spectrophotometer was used to determine chlorpropham (CIPC) concentration in aqueous solution. The method was validated in term of linearity, precision and limit of detection and limit of quantitation. The correlation coefficient of standards calibration curve of (1.0–10.0 µg/mL CIPC) was R2 = 1 with a precision (RSD%, n=10) ranged from (0.87–0.53%). The limit of detection (LOD) and limit of quantitation (LOQ) based on the regression statistics of the calibration curve data of (1.0–10.0 µg/mL CIPC) were 0.04 µg/mL and 0.11 µg/mL respectively. The activated carbon adsorbent was found to be effective for the removal approximately 80% of CIPC from aqueous solution. Several isotherm models (Langmuir, Freundlich, Tempkin and Dubinin–Radushkevich) were evaluated. The maximum monolayer sorption capacity (Qm) from the Langmuir isotherm model was determined to be (44316.92 µg/g). The separation factor (RL) is 0.11 which indicates a favorable equilibrium sorption with the R2 value of 0.99, indicating that the Langmuir isotherm model fit the experimental sorption data well.
Subject
Process Chemistry and Technology,Chemical Engineering (miscellaneous),Bioengineering
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献