Effect of Clutter Filter in High-Frame-Rate Ultrasonic Backscatter Coefficient Analysis

Author:

Omura Masaaki1ORCID,Yagi Kunimasa2,Nagaoka Ryo1,Yoshida Kenji3,Yamaguchi Tadashi3,Hasegawa Hideyuki1

Affiliation:

1. Faculty of Engineering, University of Toyama, Toyama 930-8555, Japan

2. School of Medicine, Kanazawa Medical University, Kanazawa 920-0293, Japan

3. Center for Frontier Medical Engineering, Chiba University, Chiba 263-8522, Japan

Abstract

High-frame-rate imaging with a clutter filter can clearly visualize blood flow signals and provide more efficient discrimination with tissue signals. In vitro studies using clutter-less phantom and high-frequency ultrasound suggested a possibility of evaluating the red blood cell (RBC) aggregation by analyzing the frequency dependence of the backscatter coefficient (BSC). However, in in vivo applications, clutter filtering is required to visualize echoes from the RBC. This study initially evaluated the effect of the clutter filter for ultrasonic BSC analysis for in vitro and preliminary in vivo data to characterize hemorheology. Coherently compounded plane wave imaging at a frame rate of 2 kHz was carried out in high-frame-rate imaging. Two samples of RBCs suspended by saline and autologous plasma for in vitro data were circulated in two types of flow phantoms without or with clutter signals. The singular value decomposition was applied to suppress the clutter signal in the flow phantom. The BSC was calculated using the reference phantom method, and it was parametrized by spectral slope and mid-band fit (MBF) between 4–12 MHz. The velocity distribution was estimated by the block matching method, and the shear rate was estimated by the least squares approximation of the slope near the wall. Consequently, the spectral slope of the saline sample was always around four (Rayleigh scattering), independently of the shear rate, because the RBCs did not aggregate in the solution. Conversely, the spectral slope of the plasma sample was lower than four at low shear rates but approached four by increasing the shear rate, because the aggregations were presumably dissolved by the high shear rate. Moreover, the MBF of the plasma sample decreased from −36 to −49 dB in both flow phantoms with increasing shear rates, from approximately 10 to 100 s−1. The variation in the spectral slope and MBF in the saline sample was comparable to the results of in vivo cases in healthy human jugular veins when the tissue and blood flow signals could be separated.

Funder

JSPS Moonshot R&D

JSPS Core-to-Core Program

KAKENHI

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Reference46 articles.

1. Viscoelasticity of Human Blood;Thurston;Biophys. J.,1972

2. Red-Cell Aggregation and Red-Cell Deformability in Diabetes;Volger;Diabetes,1976

3. Relationship of Blood Flow in the Common Iliac Vein to Lower Urinary Tract Disease;Sugaya;J. Med. Ultrason.,2019

4. Clutter Filter Design for Ultrasound Color Flow Imaging;Torp;IEEE Trans. Ultrason. Ferroelectr. Freq. Control,2002

5. Reduction of the Clutter Component in Doppler Ultrasound Signals Based on Singular Value Decomposition: A Simulation Study;Ledoux;Ultrason. Imaging,1997

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3