Abstract
Bearing fault is the most common failure in rotating machines, and bearing fault diagnosis (BFD) has been investigated using vibration, current, or acoustic signals. However, there are still challenges in some existing approaches. This study proposes a novel BFD method based on natural observer. Based on the analysis of the effects on the load torque signal caused by bearing faults in the permanent magnetic synchronous machine (PMSM), a modified natural observer was designed to reconstruct the load torque signal from electrical signals, acquiring a novel indicator without the additional sensor installed. Angular resampling was implemented to convert the non-stationary load torque signal into a stationary one to reduce the computational complexity. For full-auto diagnosis without human involvement, a threshold determination algorithm was also modified. Experimental validations were carried out under speed-varying and torque-varying conditions and were compared with phase current and q-axis current signals. The average signal-to-noise ratio (SNR) of the estimated load torque is about 8.65 times compared with the SNR of the traditional q-axis current. The effectiveness of the proposed method prior to the traditional PMSM bearing fault indicators is demonstrated by the order spectrum results.
Funder
Zhejiang Provincial Natural Science Foundation
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献