Fouling Mitigation by Optimizing Flow Rate and Pulsed Electric Field during Bipolar Membrane Electroacidification of Caseinate Solution

Author:

Nichka Vladlen S.,Nikonenko Victor V.ORCID,Bazinet LaurentORCID

Abstract

The efficiency of separation processes using ion exchange membranes (IEMs), especially in the food industry, is significantly limited by the fouling phenomenon, which is the process of the attachment and growth of certain species on the surface and inside the membrane. Pulsed electric field (PEF) mode, which consists in the application of constant current density pulses during a fixed time (Ton) alternated with pause lapses (Toff), has a positive antifouling impact. The aim of this study was to investigate the combined effect of three different relatively high flow rates of feed solution (corresponding to Reynolds numbers of 187, 374 and 560) and various pulse–pause ratios of PEF current regime on protein fouling kinetics during electrodialysis with bipolar membranes (EDBM) of a model caseinate solution. Four different pulse/pause regimes (with Ton/Toff ratios equal to 10 s/10 s, 10 s/20 s, 10 s/33 s and 10 s/50 s) during electrodialysis (ED) treatment were evaluated at a current density of 5 mA/cm2. It was found that increasing the pause duration and caseinate solution flow rate had a positive impact on the minimization of protein fouling occurring on the cationic surface of the bipolar membrane (BPM) during the EDBM. Both a long pause and high flow rate contribute to a more effective decrease in the concentration of protons and caseinate anions at the BPM surface: a very good membrane performance was achieved with 50 s of pause duration of PEF and a flow rate corresponding to Re = 374. A further increase in PEF pause duration (above 50 s) or flow rate (above Re = 374) did not lead to a significant decrease in the amount of fouling.

Funder

Russian Foundation for Basic Research

Natural Sciences and Engineering Research Council of Canada

Publisher

MDPI AG

Subject

Filtration and Separation,Chemical Engineering (miscellaneous),Process Chemistry and Technology

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3