Abstract
This paper presents a closed-loop calibration approach using impedance control. The process is managed by a data communication architecture based on open-source tools and designed for adaptability. The calibration procedure uses precision spheres and a kinematic coupling standard machine tool components, which are suitable for harsh industrial environments. As such, the required equipment is low cost (approximately group-separator = , 2000 [$]USD), robust, and is quick to set up, especially when compared to traditional calibration devices. As demonstrated through an experimental study and validated with a laser tracker, the absolute accuracy of the KUKA LBR iiwa robot was improved to a maximum error of 0 . 990 , representing a 58.4% improvement when compared to the nominal model. Further testing showed that a traditional calibration using a laser tracker only improved the maximum error by 58 μ m over the impedance control approach.
Subject
Artificial Intelligence,Control and Optimization,Mechanical Engineering
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献