Make It Less Complex: Autoencoder for Speckle Noise Removal—Application to Breast and Lung Ultrasound

Author:

Oliveira-Saraiva Duarte12ORCID,Mendes João12ORCID,Leote João3ORCID,Gonzalez Filipe André3ORCID,Garcia Nuno2,Ferreira Hugo Alexandre1ORCID,Matela Nuno1ORCID

Affiliation:

1. Instituto de Biofísica e Engenharia Biomédica, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisbon, Portugal

2. LASIGE, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisbon, Portugal

3. Critical Care Department, Hospital Garcia de Orta E.P.E, 2805-267 Almada, Portugal

Abstract

Ultrasound (US) imaging is used in the diagnosis and monitoring of COVID-19 and breast cancer. The presence of Speckle Noise (SN) is a downside to its usage since it decreases lesion conspicuity. Filters can be used to remove SN, but they involve time-consuming computation and parameter tuning. Several researchers have been developing complex Deep Learning (DL) models (150,000–500,000 parameters) for the removal of simulated added SN, without focusing on the real-world application of removing naturally occurring SN from original US images. Here, a simpler (<30,000 parameters) Convolutional Neural Network Autoencoder (CNN-AE) to remove SN from US images of the breast and lung is proposed. In order to do so, simulated SN was added to such US images, considering four different noise levels (σ = 0.05, 0.1, 0.2, 0.5). The original US images (N = 1227, breast + lung) were given as targets, while the noised US images served as the input. The Structural Similarity Index Measure (SSIM) and Peak Signal-to-Noise Ratio (PSNR) were used to compare the output of the CNN-AE and of the Median and Lee filters with the original US images. The CNN-AE outperformed the use of these classic filters for every noise level. To see how well the model removed naturally occurring SN from the original US images and to test its real-world applicability, a CNN model that differentiates malignant from benign breast lesions was developed. Several inputs were used to train the model (original, CNN-AE denoised, filter denoised, and noised US images). The use of the original US images resulted in the highest Matthews Correlation Coefficient (MCC) and accuracy values, while for sensitivity and negative predicted values, the CNN-AE-denoised US images (for higher σ values) achieved the best results. Our results demonstrate that the application of a simpler DL model for SN removal results in fewer misclassifications of malignant breast lesions in comparison to the use of original US images and the application of the Median filter. This shows that the use of a less-complex model and the focus on clinical practice applicability are relevant and should be considered in future studies.

Funder

Fundação para a Ciência e Tecnologia–Portugal

Bolsa de Investigação para Doutoramento

Bolsa de Investigação para Doutoramento Maria de Sousa

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Computer Graphics and Computer-Aided Design,Computer Vision and Pattern Recognition,Radiology, Nuclear Medicine and imaging

Reference40 articles.

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献