Affiliation:
1. School of Mechanical Engineering, Shandong University of Technology, Zibo 255000, China
2. Beijing Institute of Control and Electronic Technology, Beijing 100080, China
Abstract
A soft fault in an analog circuit is a symptom where the parameter range of a component exists symmetrically to the left and right of its nominal value and exceeds a specific range. The proposed method uses the Grey Wolf Optimization (GWO) optimized tunable Q-factor wavelet transform (TQWT) algorithm for feature refinement, the Inception model for feature extraction, and an SVM for fault diagnosis. First, the Q-factor is optimized to make it more compatible with the signal. Second, the signal is decomposed, and a single-branch reconstruction is performed using the TQWT to extract features adequately. Then, fault feature extraction is conducted using the Inception model to obtain multiscale features. Finally, a Support Vector Machine (SVM) is used to complete the entire fault diagnosis process. The proposed method is comprehensively evaluated using the Sallen–Key bandpass filter circuit and the four-op-amp biquad high-pass filter circuit widely used in electronic systems. The experimental results prove that the proposed method outperforms the existing methods in terms of diagnosis accuracy and reliability.
Funder
The Youth Fund of Shandong Natural Science Foundation
Natural Science Foundation of Shandong Province, China
The Youth Innovation Team Development Program of Shandong Provincial Higher Education Institutions