Abstract

An accurate and dimensionally stable trial denture base is required for a successful denture. The aim of this in vitro study was to assess the dimensional stability of a light-activated urethane dimethacrylate (UDMA) visible light cure (VLC) denture base with three fabrication techniques and different curing cycles. Forty-five VLC denture base samples were divided evenly into three groups. Group A used a conventional fabrication technique with a curing cycle of 5 min. Group B used a modified fabrication technique with two 4-min curing cycles. Group C used a multi-step fabrication technique with three curing cycles (4 min, plus 4 min, plus 2 min). The samples were sectioned and observed under a stereomicroscope to measure the discrepancy between the sample and the master cast. The mean dimensional discrepancy (mm) at the molar region at mid-palate, after 24 h in Group A, B and C was 0.790 mm, 0.741 mm and 0.379 mm, respectively; at the right ridge crest, it was 0.567, 0.408 and 0.185, while at the left ridge crest it was 0.475, 0.331 and 0.125, respectively. Statistical analysis showed significantly different dimensional discrepancies among the groups at all three sites; right ridge crest (F = 93.54, p < 0.001), left ridge crest (F = 105.96, p < 0.001) and mid-palate (F = 125.53, p < 0.001). Within the limitations of this laboratory study, it can be concluded that the denture base using a multi-step fabrication technique with three curing cycles provides better adaptation than the conventional technique. The significance of the study is that clinicians should consider performing denture base fabrication using a multi-step technique to enhance adaptation and hence the stability of the dentures for patients.

Funder

King Khalid University

Publisher

MDPI AG

Subject

Polymers and Plastics,General Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3