Computerized occlusal forces analysis in complete dentures fabricated by additive and subtractive techniques

Author:

Chaturvedi Saurabh,Addas Mohamed Khaled,Alqahtani Nasser M.,Al Ahmari Nasser M.,Alfarsi Mohammed A.

Abstract

BACKGROUND: Fabrication of complete dentures by computer-aided designing and computer-aided manufacturing (CAD-CAM) techniques are now common. Subtractive and Additive are the two principal CAD-CAM techniques used for this purpose. However, studies that evaluated the occlusal forces by CDs manufactured by these techniques are lacking. OBJECTIVES: To compare the occlusal forces in complete dentures fabricated by additive, subtractive and conventional techniques with different occlusal schemes, using computerized occlusal force analysis system [Tech-Scan III (T-scan III)]. METHODS: Three groups (Gr) were made on the basis of techniques of fabrication of CDs: Conventional CDs (CCD), Subtractive CDs (SCD), and Additive CDs (ACD). Each Group CDs were further divided into three sub groups based on occlusion schemes: bilateral balanced occlusion (BBO), lingualized occlusion (LO) and mono plane occlusion (MO). A total of 45 CDs were made: 15 in each group with 5 CDs of each occlusal scheme. For all samples, occlusal force analysis (percentage of occlusal force applied on the right and left sides of the arch, centralization of forces and percentage of maximum occlusal force) was done using computerized occlusal analysis system: T-scan III. Univariate regression analysis and logistic regression analysis were used to find the effects of the technique of fabrication and occlusion scheme over the occlusal forces (p< 0.05). RESULTS: The intergroup comparison revealed statistically significant differences (p< 0.01) in Right – Left side force difference, maximum bite force in CDs fabricated by various techniques and with different occlusion schemes. Though the effect of occlusion scheme was more than the technique of fabrication (according to effect size estimation). The maximum force difference between Right – Left side was observed in combination of CCD technique and MO scheme (36.88 ± 2.82 N). Furthermore, the maximum bite force was observed for SCD technique (89.14 ± 6.08 N) and LO scheme (92.17 ± 3.22 N). In comparison to ACD, the chances of centre of force out of ellipse was 2.53 time more in CCS and 0.75 times less in SCD techniques and in comparison to MO, the chances of out of ellipse was 0.298 times less in BBO and 0.396 times less in LO schemes, though these chances were not statistically significant (p> 0.05). CONCLUSIONS: The digital CDs fabricated by subtractive technique were proved to be superior to additive technique in terms of occlusal force analysis on tested parameters. However, further research is needed on patients to determine the exact superiority of one technique over the other.

Publisher

IOS Press

Subject

Health Informatics,Biomedical Engineering,Information Systems,Biomaterials,Bioengineering,Biophysics

Reference43 articles.

1. Current techniques in CAD/CAM denture fabrication;Baba;Gen Dent,2016

2. CAD/CAM fabricated complete dentures: concepts and clinical methods of obtaining required morphological data;Goodacre;J Prosthet Dent,2012

3. A CAD/CAM system for removable denture. Part I: fabrication of complete dentures;Maeda;Int J Prosthodont,1994

4. Trial of duplication procedure for complete dentures by CAD/CAM;Kawahata;J Oral Rehabil,1997

5. Study on CAD & RP for removable complete denture;Sun;Comput Methods Programs Biomed,2009

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3