Application of High-Performance Liquid Chromatography with Diode Array Detection to Simultaneous Analysis of Reference Antioxidants and 1,1-Diphenyl-2-picrylhydrazyl (DPPH) in Free Radical Scavenging Test

Author:

Tatarczak-Michalewska MałgorzataORCID,Flieger JolantaORCID

Abstract

Antioxidant activity can be analyzed by various methods, both in vitro and in vivo. The widely used colorimetric method using the 1,1-diphenyl-2-picrylhydrazyl (DPPH) radical scavenging reaction has many limitations, such as interference from photosynthetic pigments naturally found in plant extracts. The DPPH-HPLC eliminates these troubles by enabling the separation of the DPPH free radical (DPPH-R) peak and its reduced form (DPPH-H) from other extract components. However, simultaneous analysis of antioxidants and evaluation of their activity is more complicated. To date, a post-column reaction with DPPH has been used for this purpose. The aim of the current study was the elaboration on a DPPH-RP-HPLC in gradient elution mode for simultaneous evaluation of the antioxidant activity of standards on the basis of DPPH-R peak inhibition, together with the identification of standards, as well as the products of redox reactions. The following antioxidants (AOs) were used as standards: quercetin, resveratrol, Trolox, chlorogenic acid, hesperetin, and coumarin. Flavone was used as the control chemical without antioxidant activity. The separation of the DPPH-R/DPPH-H pair, together with standards and reaction products, was studied on a C18 column using a gradient of acetonitrile from 5 to 60% within 20 min. The stability of DPPH was evaluated with different gradient profiles. The influence of the addition of acetic acid in concentrations of 0.05 to 1%, the duration of the analysis, and the radiation emitted by the UV lamp of a diode array detector on the induction of DPPH decomposition processes were investigated. The most significant parameter affecting DPPH stability appeared to be the acidic environment and water content in the mobile phase. An increase in the water content from 70 to 95% worsened the LOD of DPPH-R from 31.64 nM to 107.31 nM, as measured at 517 nm, and from 189.41 to 1677.05 nM at 330 nm. Each gradient profile provided good linearity (R2 = 0.9790–0.9977) of the relationship between the DPPH-R as well as DPPH-H peak areas, and a wide concentration range from 0.5 to 2.5 mM for UV-vis detection. Free radical scavenging activity was expressed by the percentage of DPPH-R peak inhibition at 517 nm. This simple method is suitable for monitoring DPPH radical scavenging by AO standards.

Publisher

MDPI AG

Subject

Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3