Simple and Fast Pesticide Nanosensors: Example of Surface Plasmon Resonance Coumaphos Nanosensor

Author:

Oymen Beste1,Jalilzadeh Mitra2,Yılmaz Fatma3,Aşır Süleyman4ORCID,Türkmen Deniz2ORCID,Denizli Adil2ORCID

Affiliation:

1. Department of Gastronomy and Culinary Arts, Bahçeşehir Cyprus University, Mersin 10 Turkey, Nicosia 99010, Cyprus

2. Department of Chemistry, Faculty of Science, Hacettepe University, Beytepe, Ankara 06800, Turkey

3. Chemistry Technology Division, Vocational School of Gerede, Bolu Abant Izzet Baysal University, Bolu 14030, Turkey

4. Department of Materials Science and Nanotechnology Engineering, Near East University, Mersin 10 Turkey, Nicosia 99138, Cyprus

Abstract

Here, a molecular imprinting technique was employed to create an SPR-based nanosensor for the selective and sensitive detection of organophosphate-based coumaphos, a toxic insecticide/veterinary drug often used. To achieve this, UV polymerization was used to create polymeric nanofilms using N-methacryloyl-l-cysteine methyl ester, ethylene glycol dimethacrylate, and 2-hydroxyethyl methacrylate, which are functional monomers, cross-linkers, and hydrophilicity enabling agents, respectively. Several methods, including scanning electron microscopy (SEM), atomic force microscopy (AFM), and contact angle (CA) analyses, were used to characterize the nanofilms. Using coumaphos-imprinted SPR (CIP-SPR) and non-imprinted SPR (NIP-SPR) nanosensor chips, the kinetic evaluations of coumaphos sensing were investigated. The created CIP-SPR nanosensor demonstrated high selectivity to the coumaphos molecule compared to similar competitor molecules, including diazinon, pirimiphos-methyl, pyridaphenthion, phosalone, N-2,4(dimethylphenyl) formamide, 2,4-dimethylaniline, dimethoate, and phosmet. Additionally, there is a magnificent linear relationship for the concentration range of 0.1–250 ppb, with a low limit of detection (LOD) and limit of quantification (LOQ) of 0.001 and 0.003 ppb, respectively, and a high imprinting factor (I.F.4.4) for coumaphos. The Langmuir adsorption model is the best appropriate thermodynamic approach for the nanosensor. Intraday trials were performed three times with five repetitions to statistically evaluate the CIP-SPR nanosensor’s reusability. Reusability investigations for the two weeks of interday analyses also indicated the three-dimensional stability of the CIP-SPR nanosensor. The remarkable reusability and reproducibility of the procedure are indicated by an RSD% result of less than 1.5. Therefore, it has been determined that the generated CIP-SPR nanosensors are highly selective, rapidly responsive, simple to use, reusable, and sensitive for coumaphos detection in an aqueous solution. An amino acid, which was used to detect coumaphos, included a CIP-SPR nanosensor manufactured without complicated coupling methods and labelling processes. Liquid chromatography with tandem mass spectrometry (LC/MS-MS) studies was performed for the validation studies of the SPR.

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Mechanical Engineering,Control and Systems Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3