The efficacy of two commercially available devices for airway foreign body relief: A cadaver study

Author:

Ramaswamy Apoorva12,Done Aaron1,Solis Roberto1ORCID,Srikanth Mayuri2ORCID,Olinde Lindsay1,Belafsky Peter1

Affiliation:

1. Department of Otolaryngology, Center for Voice and Swallow University of California, Davis Sacramento California USA

2. Department of Otolaryngology The Ohio State University Columbus Ohio USA

Abstract

AbstractObjectiveForeign body aspiration events are frequent in young children and in the geriatric population. They may result in several complications such as hypoxia, edema, cardiac arrest, and death. Recently, two commercially available devices, the LifeVac and DeChoker, have entered the market with the claim of relieving foreign body aspiration. Both devices are portable, nonpowered, suction devices that are being considered for use in large public spaces such as schools, airports, and malls despite previous studies detailing variable efficacy. In this study, we aim to contribute further data on the safety and efficacy of these devices through a fresh cadaver model.MethodsCommonly aspirated foods of three different sizes (saltines, grapes, and cashews) were placed at the level of the true vocal folds in a fresh cadaver. Three participants performed two trials with each food and device. Device use was performed to manufacturer specifications.ResultsThe DeChoker resulted in gross injury to the tongue and failed to remove the obstruction in all trials. LifeVac was successful in removing the barium‐moistened saltines but failed to remove all other foreign bodies. Both devices applied significant pressure to the tongue.ConclusionWith the exception of the LifeVac removing saltine crackers, all trials were entirely unsuccessful in relieving foreign body aspiration. Additionally, both devices may cause significant pressure and injury to the oral cavity in a clinical setting. We conclude bystanders should continue to follow International Liaison Committee on Resuscitation's guidelines on resuscitation to aid with relieving foreign body aspiration.Level of Evidence4

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3