Model‐based reconstructions for intravoxel incoherent motion and diffusion tensor imaging parameter map estimations

Author:

Rauh Susanne S.1ORCID,Maier Oliver2,Gurney‐Champion Oliver J.3,Hooijmans Melissa T.3ORCID,Stollberger Rudolf2,Nederveen Aart J.3,Strijkers Gustav J.1

Affiliation:

1. Department of Biomedical Engineering and Physics, Amsterdam UMC, Amsterdam Movement Sciences University of Amsterdam The Netherlands

2. Institute of Medical Engineering Graz University of Technology Graz Austria

3. Department of Radiology and Nuclear Medicine, Amsterdam UMC, Amsterdam Movement Sciences University of Amsterdam The Netherlands

Abstract

AbstractIntravoxel incoherent motion (IVIM) imaging and diffusion tensor imaging (DTI) facilitate noninvasive quantification of tissue perfusion and diffusion. Both are promising biomarkers in various diseases and a combined acquisition is therefore desirable. This comes with challenges, including noisy parameter maps and long scan times, especially for the perfusion fraction f and pseudo‐diffusion coefficient D*. A model‐based reconstruction has the potential to overcome these challenges. As a first step, our goal was to develop a model‐based reconstruction framework for IVIM and combined IVIM‐DTI parameter estimation. The IVIM and IVIM‐DTI models were implemented in the PyQMRI model‐based reconstruction framework and validated with simulations and in vivo data. Commonly used voxel‐wise nonlinear least‐squares fitting was used as the reference. Simulations with the IVIM and IVIM‐DTI models were performed with 100 noise realizations to assess accuracy and precision. Diffusion‐weighted data were acquired for IVIM reconstruction in the liver (n = 5), as well as for IVIM‐DTI in the kidneys (n = 5) and lower‐leg muscles (n = 6) of healthy volunteers. The median and interquartile range (IQR) values of the IVIM and IVIM‐DTI parameters were compared to assess bias and precision. With model‐based reconstruction, the parameter maps exhibited less noise, which was most pronounced in the f and D* maps, both in the simulations and in vivo. The bias values in the simulations were comparable between model‐based reconstruction and the reference method. The IQR was lower with model‐based reconstruction compared with the reference for all parameters. In conclusion, model‐based reconstruction is feasible for IVIM and IVIM‐DTI and improves the precision of the parameter estimates, particularly for f and D* maps.

Funder

Österreichischen Akademie der Wissenschaften

Publisher

Wiley

Subject

Spectroscopy,Radiology, Nuclear Medicine and imaging,Molecular Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3