Effect of finish line location and saliva contamination on the accuracy of crown finish line scanning

Author:

An Hongseok1ORCID,Mickesh Grant J.2,Cho David3,Sorensen John A.4

Affiliation:

1. Department of Oral Rehabilitation and Biosciences Oregon Health & Science University School of Dentistry Portland Oregon USA

2. Graduate Prosthodontics Texas A&M University College of Dentistry Dallas Texas USA

3. New York University College of Dentistry New York New York USA

4. Department of Restorative Dentistry University of Washington School of Dentistry Seattle Washington USA

Abstract

AbstractPurposeIntraoral scanners are used widely as an alternative to conventional impressions, but studies on the influence of finish line location and saliva contamination on scanning trueness are lacking. The purpose of this in vitro study was to evaluate the influence of finish line location and saliva contamination on the scanning trueness of crown finish lines.Materials and methodsThree ivorine teeth were prepared for all‐ceramic crowns with finish lines placed equigingivally, 0.5 mm subgingivally, and 1.0 mm subgingivally. A single‐cord technique was used for gingival retraction, and a total of 180 intraoral scans were made using two intraoral scanners (Emerald; Planmeca USA Inc., Hoffman Estates, IL, USA & Trios 3; 3Shape A/S, Copenhagen, Denmark). The prepared teeth were separated from the dentoform and scanned using the same intraoral scanners to create reference scans. All scans were imported to the design software (Dental System 2019; 3Shape A/S, Copenhagen, Denmark). After marking the finish lines of prepared teeth, intraoral scans were aligned to the reference scans for comparisons. Vertical and horizontal marginal discrepancies were measured at four different measuring points (buccal, lingual, mesial, and distal) and analyzed. Two‐way ANOVA and Tukey HSD tests were used for statistical analysis (α = 0.05).ResultsThe average vertical and horizontal discrepancies from various groups ranged from −33 to 440 µm. For both intraoral scanners, subgingival finish line groups showed greater vertical and horizontal discrepancies compared with equigingival finish line groups. Saliva contamination significantly increased both vertical and horizontal discrepancies for all finish line locations. The discrepancy increases due to saliva contamination were greater for the subgingival groups.ConclusionsSubgingival finish lines were not accurately captured using the intraoral scanners. The presence of saliva significantly reduced scanning trueness, and this was amplified when the finish lines were located subgingivally.

Publisher

Wiley

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3