Accuracy of Four Intra-Oral Scanners in Subgingival Vertical Preparation: An In Vitro 3-Dimensional Comparative Analysis

Author:

Casucci Alessio1,Verniani Giulia1ORCID,Habib Ralph1,Ricci Nicolò Maria1,Carboncini Clelia2,Ferrari Marco1ORCID

Affiliation:

1. Department of Prosthodontics, University of Siena, 53100 Siena, Italy

2. Department of Periodontics, University of Turin, 10126 Turin, Italy

Abstract

One of the most critical aspects in intraoral impression is the detection of the finish line, particularly in the case of subgingival preparations. The aim of this in vitro study was to evaluate the accuracy among four different Intra Oral Scanners (IOSs) in scanning a subgingival vertical margins preparation (VP). A reference maxillary typodont (MT) was fabricated with a VP for full crown on #16 and #21. The MT was scanned with a laboratory scanner (Aadva lab scanner, GC, Tokyo, Japan) to obtain a digital MT (dMT) in .stl format file. A group of 40 digital casts (dIOC) were obtained by scanning the MT 10 times with four different IOSs: Trios 3, 3Shape A/S; I700, Medit; Vivascan, Ivoclar; and Experimental IOS, GC. All the obtained dIOCs were imported into an inspection software program (Geomagic Control X; 3D SYSTEMS) to be superimposed to the dMT in order to calculate trueness. Therefore, in order to calculate precision, all the scans of the same scanner group were superimposed onto the cast that obtained the best result of trueness. The results were collected as the root mean square value (RMS) on the #16 and #21 abutment surfaces and on a marginal area positioned 1 mm above and below the gingival margin. A nonparametric analysis Kruskal–Wallis test was performed to compare the RMS values obtained in the different iOS groups for trueness and precision. Statistical significance was set at 0.05. For the trueness on the #16 abutment, the Vivascan reported statistically lower values, while on the #21 abutment, Vivascan (56.0 ± 12.1) and Experimental IOS, GC (59.2 ± 2.7) performed statistically better than the others. Regarding precision, Experimental IOS, GC were significantly better than the others on #16 (10.7 ± 2.1) and in the #21 area Experimental, GC, and Trios 3 performed statistically better(16.9 ± 13.8; 18.0 ± 2.7). At the subgingival marginal level for both #16 and #21, all the IOS reported reduced accuracy compared to clinical acceptance.

Publisher

MDPI AG

Subject

General Materials Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3