A Randomized Controlled Clinical Trial on Lithium Disilicate Veneers Manufactured by the CAD–CAM Method: Digital Versus Hybrid Workflow

Author:

Verniani Giulia1ORCID,Ferrari Marco1ORCID,Manfredini Daniele2ORCID,Ferrari Cagidiaco Edoardo3

Affiliation:

1. Department of Prosthodontics, University of Siena, 53100 Siena, Italy

2. Orofacial Pain Unit, University of Siena, 53100 Siena, Italy

3. Department of Oral Surgery, University of Siena, 53100 Siena, Italy

Abstract

Pressed lithium disilicate is largely used for veneer manufacturing, but a new block formulation has recently been released on the market. This study evaluated the clinical performance of milled lithium disilicate veneers (LiSi Block, GC Co., Tokyo, Japan) realized with a fully digital or hybrid workflow using modified United States Public Health Service (USPHS) evaluation criteria and survival rates after 24 months of clinical service together with the patient’s satisfaction using the Visual Analog Scale (VAS). A total of 105 veneers on natural anterior teeth were made on twenty-nine patients with LiSi Block (GC, Tokyo, Japan). Patients were randomly divided into three groups: Group 1, 35 veneers realized with a completely digital workflow using Trios 3 (3Shape A/S, Copenhagen, Denmark); Group 2, 35 veneers realized with a completely digital workflow using Experimental IOS (GC, Tokyo, Japan); and Group 3, 35 veneers realized with a hybrid workflow. The restorations were followed up for 24 months, and the modified USPHS evaluation was performed at baseline, 12 months, and 24 months together with periodontal evaluation. Repeated measures two-way ANOVA and the Tukey test were applied to compare the modified USPHS method values (α = 0.05). STATISTICA 10.0 software and SIGMAPLOT 12.0 software were used to perform statistical analysis. There were no statistically significant differences between the three groups and with the interaction of group vs. time periods. The satisfaction scores of 7.35 ± 1.8 and 9.4 ± 0.37 were recorded before and after treatment, respectively. Milled lithium disilicate veneers showed a good clinical outcome after 2 years of clinical service. No difference was found between fully digital or hybrid workflow.

Publisher

MDPI AG

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3