Effect of different span lengths with different total occlusal convergences on the accuracy of intraoral scanners

Author:

Yehia Ashraf1,Abo El Fadl Ahmad1,El Sergany Omar2,Ebeid Kamal1ORCID

Affiliation:

1. Department of Fixed Prosthodontics Faculty of Dentistry, Ain Shams University Cairo Egypt

2. Department of Fixed Prosthodontics Faculty of Dentistry, British University in Egypt Cairo Egypt

Abstract

AbstractPurposeThe aim was to assess the effect of span lengths and total occlusal convergence (TOC) on the accuracy of intraoral scanners .Materials and methodsTwo typodont acrylic teeth models were prepared to receive fixed dental prostheses with three different span lengths. Span 1: between maxillary canines; span 2: between maxillary second premolars; and span 3: between maxillary second molars. In the first model, prepared teeth had a TOC of 12°, whereas, in the second model, teeth had a TOC of 20°. Each model was scanned 10 times using 4 different intraoral scanners (Omnicam, Primescan, Trios 4, and Medit i500). The STL files from the scans were compared to the reference models (trueness) and within each test group (precision) using a 3D comparison software. Data were then statistically analyzed.ResultsRegarding trueness, no significant differences were found among Primescan (32.58 ± 13.08), Trios 4 (32.33 ± 12.19), and Medit i500 (32.26 ± 9.57). However, all showed significantly better trueness than Omnicam (35.70 ± 8.35) (p < 0.001). The highest values were found in scans between the second molars (47.42 ± 3.94), followed by scans between second premolars (28.42 ± 3.78), and the highest trueness was found in scans between the canines (23.80 ± 3.85). For TOC, 12° had a significantly higher value than 20° (p < 0.001). Regarding precision, the highest values were found with Omnicam (29.84 ± 3.89), followed by Medit i500 (28.04 ± 2.94), then Trios 4 (25.64 ± 3.11), and Primescan (24.69 ± 5.25). The highest values and least precision were found in scans between the second molars (28.97 ± 5.27) and scans between second premolars (27.59 ± 3.97), whereas the highest precision was found in scans between the canines (24.60 ± 2.04). For TOC, 12° had significantly higher values than 20° (p < 0.001).ConclusionsIntraoral scans are directly affected by scanner type, TOC, and scan spans. All tested scanners showed clinically acceptable results even for long‐span restorations.

Publisher

Wiley

Subject

General Dentistry

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3