Analysis of accuracy of twelve intraocular lens power calculation formulas for eyes with axial hyperopia

Author:

Stopyra Wiktor1

Affiliation:

1. MW Med Eye Centre, Cracow, Poland

Abstract

PURPOSE: The purpose was to compare twelve intraocular lens power calculation formulas for eyes smaller than 22.0 mm in terms of absolute error (AE), the percentage of postoperative emmetropia, and agreement interval in Bland–Altman analysis. METHODS: The data of hyperopic patients who underwent uneventful phacoemulsification between January 2016 and July 2021 were reviewed. Intraocular lens power was calculated using Holladay 1, SRK/T, Hoffer Q, Holladay 2, Haigis, Barrett Universal II, Hill-RBF, Ladas, Kane, Emmetropia Verifying Optical (EVO), Pearl-DGS, and K6 formulas. Three months after phacoemulsification, refraction was measured, and the mean AE was calculated. The percentage of patients with full visual acuity (VA) without any correction, with ± 0.25D, ±0.5D, ±0.75D, and limits of agreement for each formula was established. RESULTS: Seventy-two patients, whose ocular axial length (AL) ranged between 20.02 mm and 21.98 mm, were included. The Kane formula achieved the lowest mean AE of 0.09 ± 0.09 just before EVO (0.12 ± 0.09), Hill-RBF (0.17 ± 0.12), and Hoffer Q formulas (0.19 ± 0.16). In addition, with the Kane formula, the percentage of patients with full VA without any correction (80.6%) was the highest ahead of EVO and Hoffer Q formulas (51.5% and 50.0%, respectively). Finally, Kane, EVO, and Hill-RBF obtained the lowest agreement interval (0.4923, 0.5815, and 0.7740, respectively). CONCLUSION: The Kane formula is recommended for intraocular lens power calculation for eyeballs with the AL smaller than 22.0 mm. The EVO formula gives very promising results in regarding the accuracy of intraocular lens power for hyperopic eyes.

Publisher

Medknow

Reference37 articles.

1. A comparative study to assess the predictability of different IOL power calculation formulas in eyes of short and long axial length;Doshi;J Clin Diagn Res,2017

2. Biometry and intraocular lens power calculation;Lee;Curr Opin Ophthalmol,2008

3. Precision of intraocular lens power prediction in eyes shorter than 22 mm:An analysis of 6 formulas;Shrivastava;J Cataract Refract Surg,2018

4. Project hyperopic power prediction:Accuracy of 13 different concepts for intraocular lens calculation in short eyes;Wendelstein;Br J Ophthalmol,2022

5. Comparing the accuracy of new intraocular lens power calculation formulae in short eyes after cataract surgery:A systematic review and meta-analysis;Luo;Int Ophthalmol,2022

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3