Comparison of Far and near Contrast Sensitivity in Patients Symmetrically Implanted with Multifocal and Monofocal Iols

Author:

Gil Miguel A.1,Varón Consuelo2,Cardona Genís2,Vega Fidel3,Buil José A.1

Affiliation:

1. Ophthalmology Department, Santa Creu and Sant Pau Hospital, Barcelona - Spain

2. University Vision Centre, Department of Optics and Optometry, Technical University of Catalonia, Terrassa - Spain

3. Applied Optics and Image Processing Group, Department of Optics and Optometry, Technical University of Catalonia, Terrassa - Spain

Abstract

Purpose A prospective, randomized, double-masked, clinical trial was designed to evaluate distance and near contrast sensitivity (CS) in patients symmetrically, and randomly, implanted with 4 different multifocal intraocular lens (MIOL) designs (ReSTOR SN6AD1, ReSTOR SN60D3, ReZoom NXG, and Tecnis ZMA00) and a monofocal control group (Tecnis ZA9003), 6 months after cataract intervention. Methods Photopic, mesopic, and mesopic with glare distance CS, as well as photopic near CS, was evaluated with the CSV-1000 CS test and the Vistech VCTS 6000 system, respectively, in a group of 180 patients attending the ophthalmology department of Sant Pau Hospital, Barcelona, for cataract intervention and lens implantation. Results Statistically and clinically significant differences were found between the monofocal and multifocal lens groups at all spatial frequencies and illumination conditions, both during distance and near CS evaluation (all p<0.05), with the monofocal lens offering the best performance in all cases. Contrast sensitivity was similarly compromised in all MIOL models at distance, although MIOLs with diffractive optics and aspheric profiles showed a non–statistically significant trend to perform better in mesopic conditions. Near CS was lower for refractive, distance dominant lens designs, particularly at medium to high spatial frequencies. Conclusions The present results, which reflect intraocular lens (IOL) characteristics in optics, profile, and add power, may contribute to help surgeons decide on the type of IOL most suitable for each patient by taking into consideration the individual needs for critical distance and near vision, both in terms of visual acuity and contrast sensitivity.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3