Validation of a New Test for Measuring the Contrast Sensitivity Function (Optopad-CSF) at Near Vision

Author:

de Fez Dolores1ORCID,García Celia1ORCID,Luque-Cobija Maria Josefa2ORCID,Mena-Guevara Kevin J.1ORCID,Daudén Paula2ORCID,Piñero David P.1ORCID

Affiliation:

1. Psychophysics and Visual Perception Group, Department of Optics, Pharmacology and Anatomy, University of Alicante, 03690 San Vicente del Raspeig, Spain

2. Department of Optics, Optometrý and Visual Sciences, University of Valencia, Burjassot, 46100 Valencia, Spain

Abstract

Our purpose is to develop and validate a new iPad-based contrast sensitivity (CS) test for measuring the contrast sensitivity function at near vision (Optopad-CSF). A total of 200 eyes of 100 healthy subjects (ages 17–63) were evaluated in a comparative study between the Optopad-CSF test (near vision) and the CSV-1000E test (distance vision). The agreement between tests was assessed with the index of contrast sensitivity (ICS) and the area under the curve (AUC). CS for all the spatial frequencies in both eyes showed a negative significant correlation with age, and corrected distance, and near visual acuities (r ≤ −0.512, p ≤ 0.013). A significantly lower CS was found with the Optopad-CSF test in the over-40-year-old subgroup for all the spatial frequencies evaluated compared to the below-40 subgroup (p ≤ 0.008). The mean AUC of the Optopad-CSF test (5.84) was twice that of the CSV-1000E test (2.76). The mean ICS of the Optopad-CSF (−0.019) and CSV-1000E (−0.075) tests showed similar values, both close to 0 (p = 0.3). There was a weak but significant correlation between the Optopad-CSF and CSV-1000E ICS tests (r = 0.246, p < 0.02). A range of normality for the values obtained with the Optopad-CSF test was calculated. The mean CS values in 16 bilateral cataract patients were out of the normal range for all the spatial frequencies evaluated (p < 0.001). Optopad-CSF is a valid portable system for measuring CS at near vision for five spatial frequencies, allowing the detection of age-related changes in CSF with age and CSF loss in cataracts, with no ceiling effect.

Funder

Generalitat Valenciana

Publisher

MDPI AG

Reference30 articles.

1. (2024, March 25). Vision and Hearing Loss, 30 January 2023. World Health Organization. Available online: https://www.who.int/europe/news-room/fact-sheets/item/vision-and-hearing-loss.

2. (2024, March 25). HACSS: Holladay Automated Contrast Sensitivity System. Available online: https://www.mstech-eyes.com/products/detail/hacss-holladay-automated-contract-sensitivity-system.

3. (2024, March 25). OCST: Online Contrast Sensitivity Test. Available online: https://www.vcstest.com.

4. Designing a new test for contrast sensitivity function measurement with iPad;Monsoriu;J. Optom.,2014

5. Colorimetric Characterization of Mobile Devices for Vision Applications;Luque;Optom. Vis. Sci.,2016