The influence of pupil diameter upon and subjective quality of vision following implantable collamer lens (ICL V4c) implantation: An observational study

Author:

Zhang Qing,Wu Yi12,Huang He1,Qin Guanghao1,Li Liangzhe1,Chen Jiayan1,Che Huixin1,Xu Ling1,Moore Jonathan E.3,He Wei1,Yu Sile1,Pazo Emmanuel Eric1ORCID,He Xingru1

Affiliation:

1. He Eye Specialist Hospital, Shenyang, China

2. The Second Affiliated Hospital of Dalian Medical University, Dalian, China

3. Cathedral Eye Clinic, Belfast, UK.

Abstract

This study aimed to assess the change in pupil size and its influence on subjective quality of vision (QoV) in subjects with implanted collamer lenses (ICLs). This retrospective study assessed 53 participants (53 eyes) implanted with ICL (V4c) and categorized them into incremental groups according to pupil diameter. Preoperative and postoperative photopic and mesopic pupil diameter, uncorrected distance visual acuity (UDVA), and QoV questionnaire scores were assessed and compared. Postoperatively, at 3 months, UDVA was −0.10 ± 0.06 logarithm of the minimum angle of resolution (LogMAR), and mean QoV for day and night was 9.34 ± 0.76 and 8.58 ± 1.29, respectively. The mean mesopic and photopic pupil diameters were 6.59 ± 0.79 mm and 4.61 ± 0.74 mm, respectively. Photopic pupil diameter negatively correlated with “QoV day” (Rs = −0.413, P = .001), positively correlated with “haloes” (Rs = 0.568*, P < .001) and “blurred vision” (Rs = 0.243, P = .04) respectively. Mesopic pupil diameter negatively correlated with “QoV night” (Rs = −0.426, P = .001), positively correlated with “haloes” (Rs = 0.624*, P < .001), “starburst” (Rs = 0.233, P = .046) and “difficulty focusing” (Rs = 0.27, P = .025), respectively. Participants had excellent VA at 3-month follow-up. Photopic and mesonic pupil diameter negatively correlated with QoV day and QoV night scores, respectively. Pupil diameter was found to have a more significant effect on visual symptoms at night, and lower QoV due to larger pupil size was more noticeable at night. Further investigation is needed to explore the importance of pupil diameter and its impact on the QoV in ICL implanted patients.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3