Prospective Randomized Multicenter Comparison of the Clinical Outcomes of V4c and V5 Implantable Collamer Lenses: A Contralateral Eye Study

Author:

Kojima Takashi1ORCID,Kitazawa Yoshihiro2,Nakamura Tomoaki1,Takahashi Masahide3,Kamiya Kazutaka3ORCID,Ichikawa Kazuo4,Igarashi Akihito5,Shimizu Kimiya5ORCID

Affiliation:

1. Nagoya Eye Clinic, Nagoya, Japan

2. Kobe Kanagawa Eye Clinic, Tokyo, Japan

3. School of Allied Health Sciences, Kitasato University, Kanagawa, Japan

4. Chukyo Eye Clinic, Nagoya, Japan

5. Department of Ophthalmology, Sanno Hospital, Tokyo, Japan

Abstract

Purpose. To compare the visual and refractive outcomes and night vision performance questionnaire results between V4c and V5 implantable Collamer lenses in a prospective, randomized, multicenter study.Settings. Four refractive surgery centers.Design. Prospective randomized multicenter single-masked comparative study.Methods. Twenty-three patients were enrolled in this study. A conventional V4c model (EVO Visian ICL) was implanted in one eye, and a V5 model (EVO+ Visian ICL), which has a larger optic diameter than the V4c model, was implanted in the contralateral eye. The uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) were evaluated before and 6 months after surgery. At 6 months after surgery, a questionnaire on night vision disturbances was administered. The efficacy, safety, and predictability of the two implanted ICL models were compared.Results. There were no significant differences in the postoperative UDVA and CDVA between the two ICL models. The mean efficacy indexes for the V4c and V5 lenses were 1.16 ± 0.22 and 1.03 ± 0.23, respectively. The mean safety indexes of the V4c and V5 lenses were 1.21 ± 0.20 and 1.19 ± 0.20, respectively. The night vision performance questionnaire revealed that 7 patients (37%) noticed a difference in visual performance between the eyes, and all of them reported that they could see better at night with the V5-implanted eye compared with the V4c-implanted eye.Conclusion. The V4c and V5 ICL models achieved similar visual and refractive outcomes, whereas the V5 model showed a possible advantage in reducing night vision disturbances.

Publisher

Hindawi Limited

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3