Validation and clinical application of a method to quantify efavirenz in cervicovaginal secretions from flocked swabs using liquid chromatography tandem mass spectrometry

Author:

Olagunju AdeniyiORCID,Nwogu Jacinta,Eniayewu Oluwasegun,Atoyebi ShakirORCID,Amara Alieu,Kpamor John,Bolaji Oluseye,Adejuyigbe Ebunoluwa,Owen AndrewORCID,Khoo Saye

Abstract

Background: A liquid chromatography tandem mass spectrometry method to quantify drugs in dried cervicovaginal secretions from flocked swabs was developed and validated using the antiretroviral efavirenz as an example. Methods: Cervicovaginal swabs (CVS) were prepared by submerging flocked swabs in efavirenz-spiked matrix. Time to full saturation, weight uniformity, recovery and room temperature stability were evaluated. Chromatographic separation was on a reverse-phase C18 column by gradient elution using 1mM ammonium acetate in water/acetonitrile at 400 µL/min. Detection and quantification were on a TSQ Quantum Access triple quadrupole mass spectrometer operated in negative ionisation mode. The method was used to quantify efavirenz in CVS samples from human immunodeficiency virus (HIV)-positive women in the VADICT study (NCT03284645). A total of 98 samples (35 paired intensive CVS and DBS samples, 14 paired sparse CVS and DBS samples) from 19 participants were available for this analysis. Results: Swabs were fully saturated within 15 seconds, absorbing 128 µL of matrix with coefficient of variation (%CV) below 1.3%. The method was linear with a weighting factor (1/X) in the range of 25-10000 ng/mL with inter- and intra-day precision (% CV) of 7.69-14.9%, and accuracy (% bias) of 99.1-105.3%. Mean recovery of efavirenz from CVS was 83.8% (%CV, 11.2) with no significant matrix effect. Efavirenz remained stable in swabs for at least 35 days after drying and storage at room temperature. Median (range) CVS efavirenz AUC0-24h was 16370 ng*h/mL (5803-22088), Cmax was 1618 ng/mL (610-2438) at a Tmax of 8.0 h (8.0-12), and Cmin was 399 ng/mL (110-981). Efavirenz CVS:plasma AUC0-24 ratio was 0.41 (0.20-0.59). Conclusions: Further application of this method will improve our understanding of the pharmacology of other therapeutics in the female genital tract, including in low- and middle-income countries.

Funder

Wellcome Trust

Publisher

F1000 Research Ltd

Subject

General Biochemistry, Genetics and Molecular Biology,Medicine (miscellaneous)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3