Radiation reduction of minimally invasive transforaminal lumbar interbody fusion with localisation system in overweight patients

Author:

Fan G.1,Fu Q.2,Zhang J.3,Zhang H.1,Gu X.1,Wang C.1,Gu G.1,Guan X.1,Fan Y.1,He S.1

Affiliation:

1. Tongji University School of Medicine, 301 Yanchang Road, Shanghai 200072, China.

2. Ningbo No.2 Hospital, 41 Northwestern Road, Ningbo, Zhejiang 315099, China

3. Southeast Hospital affiliated to Xiamen University, 269 Zhanghua Road, Zhangzhou, Fujian 363020, China.

Abstract

Aims Minimally invasive transforaminal lumbar interbody fusion (MITLIF) has been well validated in overweight and obese patients who are consequently subject to a higher radiation exposure. This prospective multicentre study aimed to investigate the efficacy of a novel lumbar localisation system for MITLIF in overweight patients. Patients and Methods The initial study group consisted of 175 patients. After excluding 49 patients for various reasons, 126 patients were divided into two groups. Those in Group A were treated using the localisation system while those in Group B were treated by conventional means. The primary outcomes were the effective radiation dosage to the surgeon and the exposure time. Results There were 62 patients in Group A and 64 in Group B. The mean effective dosage was 0.0217 mSv (standard deviation (sd) 0.0079) in Group A and 0.0383 mSv (sd 0.0104) in Group B (p <  0.001). The mean fluoroscopy exposure time was 26.42 seconds (sd 5.91) in Group A and 40.67 seconds (sd 8.18) in Group B (p < 0.001). The operating time was 175.56 minutes (sd 32.23) and 206.08 minutes (sd 30.15) (p < 0.001), respectively. The mean pre-operative localisation time was 4.73 minutes (sd 0.84) in Group A and 7.03 minutes (sd 1.51) in Group B (p < 0.001). The mean screw placement time was 47.37 minutes (sd 10.43) in Group A and 67.86 minutes (sd 14.15) in Group B (p < 0.001). The pedicle screw violation rate was 0.35% (one out of 283) in Group A and 2.79% (eight out of 287) in Group B (p = 0.020). Conclusion The study shows that the localisation system can effectively reduce radiation exposure, exposure time, operating time, pre-operative localisation time, and screw placement time in overweight patients undergoing MITLIF. Cite this article: Bone Joint J 2017;99-B:944–50.

Publisher

British Editorial Society of Bone & Joint Surgery

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3