Surgeon and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusion

Author:

Bindal Rajesh K.12,Glaze Sharon34,Ognoskie Meghann1,Tunner Van1,Malone Robert3,Ghosh Subrata12

Affiliation:

1. 1Section of Neurosurgery and

2. 3Departments of Neurosurgery and

3. 2Department of Radiology, Methodist Sugar Land Hospital, Sugar Land; and

4. 4Radiology, Baylor College of Medicine Houston, Texas

Abstract

Object Minimally invasive transforaminal lumbar interbody fusion (TLIF) is an increasingly popular procedure. The technique involves use of fluoroscopy to assist with pedicle screw (PS) placement. The potential exists for both the surgeon and the patient to become exposed to significant amounts of radiation. The authors undertook this study to quantify the radiation dose to the surgeon and patient during minimally invasive TLIF. Methods The authors undertook a prospective study of 24 consecutive patients who underwent minimally invasive TLIF. All surgeries were performed by the senior author (R.K.B.), who used techniques previously described. The surgeon wore a radiation monitor under an apron-style lead shield at waist level, at an unshielded collar location, and as a sterile ring badge containing a thermoluminescent dosimeter on the dominant (right) hand ring finger. Dosimeter readings were obtained for each case. A total of 33 spinal levels were treated in 24 patients. All treated levels were between L3–4 and L5–S1. In all cases of 1-level disease, 4 PSs were placed, and in all cases of 2-level disease, 6 screws were placed. Results . Mean fluoroscopy time was 1.69 minutes per case (range 3.73–0.82 minutes). Mean exposure per case to the surgeon on his dominant hand was 76 mRem, at the waist under a lead apron was 27 mRem, and at an unprotected thyroid level was 32 mRem. Mean exposure to the patient's skin was 59.5 mGy (range 8.3–252 mGy) in the posteroanterior plane and 78.8 mGy (range 6.3–269.5 mGy) in the lateral plane. Conclusions To the authors' knowledge, this is the first study of radiation exposure to the surgeon or patient in minimally invasive TLIF. Patient exposures were low and compare favorably with exposures involving other common interventional fluoroscopically guided procedures. Surgeon exposures are limited but require careful monitoring. Annual dose limits could be exceeded if a large number of these and other fluoroscopically guided procedures were performed.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司